T/CPQS E0006-2022 Gas-fueled heating and hot water system for a water heater gas-fueled heating and hot water system
T/CPQS E0006-2022 Gas-fueled heating and hot water system for a water heater gas-fueled heating and hot water system
Basic Information
Scope
Scope: This document applies to heating boilers with a rated thermal load of less than 100 kW, a maximum heating water pressure of not more than 0.6 MPa, and an operating water temperature of not more than 95 °C, which use atmospheric or fully premixed burners, including: a) Type 1P and Type 1G forced air-intake and exhaust heating boilers specified in Appendix A of GB 25034-2020; b) Type 9P and Type 9G forced air-intake and exhaust fully premixed condensing boilers with a thermal load of more than 70 kW specified in Appendix A of GB 25034-2020; c) Type 10Z, Type 10P, and Type 10G outdoor heating boilers specified in Appendix A of GB 25034-2020. The gas referred to in this document is artificial gas, natural gas, and liquefied petroleum gas specified in GB/T 13611. Main technical contents: This document specifies the terms and definitions, classification and models, general requirements and performance requirements, test methods, inspection rules, marking, warnings, and instructions, as well as packaging, transportation, and storage for gas heating water boilers (hereinafter referred to as "appliances").