GB 4793-2024 Pending

GB 4793-2024 Safety technical specification for electrical equipment for measurement,control and laboratory use

This document specifies the safety requirements for electrical equipment used in measurement, control, and laboratory applications, including marking and documentation, protection against electric shock, prevention of mechanical hazards, resistance to mechanical stress, prevention of flame spread, temperature limits and heat resistance of equipment, prevention of hazards from fluids and solid foreign objects, protection against radiation (including laser sources) and sound pressure and ultrasonic pressure, protection against released gases and substances, and prevention of explosions and internal explosions. This document applies to the design, production, inspection, and use of electrical equipment used in measurement, control, and laboratory applications (including industrial automation equipment).

Publish Date: 2024-10-28

GB/T 42125.1-2024 Pending

GB/T 42125.1-2024 Safety requirements for electrical equipment for measurement,control and laboratory use—Part 1:General requirements

1.1.1 Equipment to which this document applies
The main purpose of this document is to serve as a safety standard for the products mentioned in its scope, but it also applies to documents developed by technical committees based on the principles set forth in IEC Guide 104 and ISO/IEC Guide 51 for products similar to those mentioned in this document's scope.
This document specifies general safety requirements for electrical equipment and its accessories intended for the following types of use, regardless of where they are used.
a) Electrical test and measurement equipment

Publish Date: 2024-10-26

GB/T 4706.123-2024 Pending

GB/T 4706.123-2024 Safety of household and similar electrical appliances—Part 123:Particular requirements for electrical hangers

The chapter of GB/T 4706.1—2024 is replaced by the following content.
This document specifies the safety of electric clothes dryers for household and similar purposes.
This document applies to electric clothes dryers for household and similar purposes with a rated voltage of not more than 250 V for single-phase appliances.
Appliances that are not intended for general household use but may still pose a risk to the public, such as electric clothes dryers intended for use by non-professional personnel in shops, offices, hotels, restaurants, hospitals, schools, light industry, and farms, are also within the scope of this document.

Publish Date: 2024-10-26

GB/T 4706.124-2024 Pending

GB/T 4706.124-2024 Safety of household and similar electrical appliances—Part 124:Particular requirements for commercial vacuum packaging appliances

This document specifies the safety requirements for household and similar-use electrical appliances.
This document applies to household and similar-use electrical appliances with a rated voltage of not more than 250 V for single-phase appliances, and a rated voltage of not more than 480 V for other appliances.
This document specifies the safety of commercial electric packaging appliances used for food preservation under vacuum conditions.
This document applies to commercial vacuum packaging appliances with a rated voltage of not more than 250 V for single-phase appliances, and a rated voltage of not more than 480 V for other appliances.
These appliances are not intended for household or similar use. Instead, they are used for commercial food preservation in areas not open to the public, such as restaurants, cafeterias, hospital kitchens, and commercial enterprises like bakeries and slaughterhouses.

Publish Date: 2024-10-26

GB/Z 44877-2024 Pending

GB/Z 44877-2024 Sterilization of medical devices—Guidance on using parametric release for ethylene oxide sterilization process

This document provides guidelines for product sterilization release using a parameter-based release method after the ethylene oxide sterilization process, in order to meet the requirements of GB 18279-2023.
This document is applicable to providing a method for parameter-based release for existing sterilization processes, as well as for developing and implementing parameter-based release standards for new sterilization processes. This document emphasizes the importance and interrelationship of other process factors that affect the reproducibility of the ethylene oxide sterilization process, such as loading methods and equipment performance. Note: For ease of use, the clause numbers in this document correspond to those in GB 18279-2023. Clauses that are consistent with GB 18279-2023 are described as "not specified or additional guidance provided", while clauses that are inconsistent have corresponding content added or modified. This document is not applicable to biological indicators. For qualified statements of sterilization cycles that include the requirement that biological indicators show no microbial growth, this document does not provide additional guidance.

Publish Date: 2024-10-26

GB/T 14233.3-2024 Pending

GB/T 14233.3-2024 Test methods for infusion,transfusion,injection equipments for medical use—Part 3:Microbiological test methods

This document describes the sterility testing of medical infusions, blood transfusions, and injection devices, as well as bacterial endotoxin testing, bioburden determination, and sterility testing methods.
This document is applicable to medical infusions, blood transfusions, and injection devices.

Publish Date: 2024-10-26

GB/T 42125.3-2024 Pending

GB/T 42125.3-2024 Safety requirements for electrical equipment for measurement,control and laboratory use—Part 3:Particular requirements for refrigerating equipment

1.1.1 Equipment to which this document applies
The main purpose of this document is to serve as a safety standard for products mentioned in its scope, but it also applies to documents developed by technical committees based on the principles stipulated in IEC Guide 104 and ISO/IEC Guide 51 for products similar to those mentioned in this document's scope.
This document specifies general safety requirements for electrical equipment and their accessories intended for the following types of use, regardless of their location.
a) Electrical testing and measurement equipment
Addition:
Add the following new item after item j):
aa) Transcritical refrigerant systems (using CO2) or systems using ammonia (NH3) as refrigerants.

Publish Date: 2024-10-26

GB/T 42125.4-2024 Pending

GB/T 42125.4-2024 Safety requirements for electric equipment for measurement,control,and laboratory use—Part 4:Particular requirements for climatic and environmental testing and other temperature conditioning equipment

1.1.1 Equipment to which this document applies
The main purpose of this document is to serve as a safety standard for products mentioned in its scope, but it also applies to documents developed by technical committees based on the principles set forth in IEC Guide 104 and ISO/IEC Guide 51 for products similar to those mentioned in the scope of this document.
This document specifies general safety requirements for electrical equipment and its accessories intended for the following types of use, regardless of their location.
a) Electrical test and measurement equipment
Addition:
Add the following items after item j):
aa) Heating, cooling, and ventilation equipment for laboratories;
bb) Sterilization equipment.

Publish Date: 2024-10-26

GB 44703-2024 Pending

GB 44703-2024 General requirements for optical radiation safety

This document specifies the general requirements for the risk classification, labeling, and safety control of optical radiation safety for laser products and incoherent light products and their operating processes.
This document applies to the optical radiation safety of laser products in the wavelength range of 180 nm to 1 mm and incoherent light products in the wavelength range of 200 nm to 3 μm, as well as their operating processes.

Publish Date: 2024-09-29

YY 1105-2024 Pending

YY 1105-2024 Electirc apparatus for gastric lavage

This document specifies the safety and performance requirements for electric gastric lavage machines and describes the corresponding test methods.
This document is applicable to electric gastric lavage machines used for clinical gastric lavage on adult patients in medical institutions.

Publish Date: 2024-09-29

YY 0790-2024 Pending

YY 0790-2024 Hemoperfusion equipment

This document specifies the requirements for blood perfusion equipment and describes the corresponding test methods.
This document applies to the blood perfusion equipment defined in 3.1 (hereinafter referred to as the equipment).
This document does not apply to:
—— Peritoneal dialysis equipment;
—— Centrifugal blood component separation equipment;
—— Continuous blood purification equipment;
—— Plasma exchange equipment;
—— Plasma adsorption equipment;
—— Hemodialysis equipment.

Publish Date: 2024-09-29

YY 0271.2-2024 Pending

YY 0271.2-2024 Dentistry—Water-based cements—Part 2:Resin-modified cements

This document specifies the requirements for resin-modified dental adhesives used for bonding, underlayment or lining, restoration, and fabrication of dental posts and cores, and describes the corresponding test methods. This document applies to resin-modified water-based dental adhesives that are cured through a combination of various reactions, including acid-base reactions and polymerization reactions. For example, traditional polyacrylic acid-based glass ionomer dental adhesives are typically produced by the reaction of an ion-releasing aluminosilicate glass with polyacrylic acid in a water environment. The adhesives covered in this document can typically be cured either through water-based acid-base reactions or polymerization reactions. Note: Manufacturers and testing institutions should pay attention to the closely related international standards ISO 4049 (YY 1042-2023/ISO 4049:2019, MOD) and ISO 9917-1 (YY 0271.1-2016/ISO 9917-1:2007, MOD). When evaluating any specific product, the most suitable of the aforementioned standards should be considered for application.

Publish Date: 2024-09-29