GB/T 23753-2020 Active National standards

GB/T 23753-2020 Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors

GB/T 23753-2020 Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors

Publish Date: 2020-11-19 Implement Date: 2021-06-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 23753-2020
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Transformer
ICS Name: Transformers, reactors, and inductors
Publish Date: 2020-11-19
Implement Date: 2021-06-01
Pages: 51 pages

Scope

This standard specifies the terms and definitions, usage conditions, performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation, and storage of oil-immersed parallel reactors (hereinafter referred to as reactors) with a nominal system voltage of 110 kV and above. It also specifies the performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation, and storage of neutral point grounding reactors used with oil-immersed parallel reactors of 110 kV and above.
This standard applies to single-phase and three-phase oil-immersed parallel reactors with a rated frequency of 50 Hz and a nominal system voltage of 110 kV and above, as well as neutral point grounding reactors used with oil-immersed parallel reactors of 110 kV and above.
For reactors with special requirements, such as adjustable reactors, if the rated impedance band is ±5% or ±10% taps and the capacity of the reactor is adjusted by the no-load tap-changer, the technical requirements of such reactors can be referenced for use.

Development Information

Word Count: 97 Thousand words Pages: 51 pages

Replace the following standards

Referenced Standards

GB 1094.1-1996 Power transformers—Part 1:General GB/T 1094.1-2013 Power transformers—Part 1:General GB 1094.2-1996 Power transformers—Part 2:Temperature rise GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers GB/T 1094.3-2003 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air GB/T 1094.6-2011 Power transformers—Part 6:Reactors GB/T 1094.10-2003 Power transformers—Part10:Determination of sound levels GB/T 1094.10-2022 Power transformers—Part 10:Determination of sound levels GB 2536-1990 Transformer oils GB 2536-2011 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear GB/T 2900.95-2015 Electrotechnical terminology—transformers,voltage regulators and reactors GB/T 4109-1999 Technical specification of high voltage bushing GB/T 4109-2008 Insulated bushings for alternating voltages above 1 000 V GB/T 4109-2022 Insulated bushings for alternating voltages above 1 000 V GB/T 5273-1985 Terminals for transformers,high-voltage apparatus and bushings GB/T 5273-2016 Dimensional standardisation of terminals for high-voltage apparatus GB/T 11604-2015 Testing procedure of radio interference generated by high voltage equipment GB/T 20840.2-2014 Instrument transformers—Part 2:Additional requirements for current transformers GB/T 26218.2-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 2:Ceramic and glass insulators for a.c.systems DL/T 722-2014 Guidelines for analyzing and evaluating the dissolved gases in transformer oil DL/T 722-2000 Guidelines for analyzing and evaluating the dissolved gases in transformer oil GB 2536-2025 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear