Scope

Main Technical Content: 4. Testing Conditions 4.1 Environmental Conditions 4.1.1 Temperature and Humidity The temperature of the testing room shall be controlled within the range of 19°C to 27°C, and the environmental humidity shall be controlled within the range of 35% to 65%. 4.1.2 Lighting The illumination in the testing area shall meet the technical requirements of the barcode tester. If no such requirements exist, the illumination in the testing area shall not exceed 100 lux. 4.2 Testing Equipment The company shall be equipped with barcode testing instruments that comply with the requirements of GB/T 18348-2008. 4.2.1 Barcode Tester 4.2.1.1 Basic Functions The barcode tester shall be able to measure the grade parameters of barcode symbols in accordance with the provisions of GB/T 18348-2008. 4.2.1.2 Measuring Wavelength The wavelength of the measurement light shall be 670nm ± 10nm. 4.2.1.3 Measuring Aperture The selection of the measuring aperture is shown in Table 1. Table 1: Selection of Measuring Aperture Barcode Symbol Type X Dimension (mm) Nominal Value of Measuring Aperture (mm) Reference Number EAN-13, EAN-8, UPC-A, UPC-E 0.264≤X≤0.66 0.150 ITF-14 0.250≤X<0.635 0.25 UCC/EAN-128 0.250≤X<0.495 0.150 0.495≤X≤1.016 0.2510 Note: X dimension refers to the width of the module. 4.2 Measuring Instruments 4.2.2.1 Magnification Coefficient The measuring instrument shall use the barcode measuring ruler provided by the China Item Code Center to measure. 4.2.2.2 Blank Area Width The minimum division value of the length measuring instrument shall not exceed 0.1mm. 4.2.2.3 X Dimension and Bar Height The minimum division value of the steel ruler shall not exceed 0.5mm. 4.3 Sampling In the sampling inspection of the quality of commodity barcodes, the barcode proofs, semi-finished and finished products shall be randomly selected by the inspectors for testing, and the number

Development Information

Same series standard

Related Standards

Contact Us