GB/T 1985-2014 High-voltage alternating-current disconnectors and earthing switches
GB/T 1985-2014 High-voltage alternating-current disconnectors and earthing switches
Basic Information
Standard Code:
GB/T 1985-2014
Standard Type:
National standards
Standard Status:
Replaced
is_force_gb:
no
CCS Name:
High-voltage switchgear
ICS Name:
High-voltage switchgear and controllers
Publish Date:
2014-06-24
Implement Date:
2015-01-22
Pages:
101 pages
Scope
This standard applies to terminals that are enclosed and open AC disconnect switches and grounding switches designed for installation indoors and outdoors, and operating in systems with a frequency of 50 Hz and a nominal voltage of 3,000 V and above.
This standard also applies to the operating mechanisms and auxiliary equipment of these disconnect switches and grounding switches.
The additional requirements for disconnect switches and grounding switches in enclosed switchgear and control equipment are specified in GB 3906, GB 7674, and IEC 62271201.
Development Information
Replace the following standards
Superseded by the following standards
Referenced Standards
GB/T 311.1-2012 Insulation co-ordination—Part 1:Definitions,principles and rules
GB/T 311.2-2013 Insulation co-ordination—Part 2:Application guide
GB/T 1804-2000 General tolerances for linear and angular dimensions without individual tolerance indications
GB/T 1984-2014 High-voltage alternating-current circuit-breakers
GB/T 2900.20-1994 Electrotechnical terminology—High-voltage switchgear
GB/T 3906-2006 Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
GB/T 4109-2008 Insulated bushings for alternating voltages above 1 000 V
GB/T 4208-2008 Degrees of protection provided by enclosure(IP code)
GB/T 4473-2008 Synthetic testing of High-voltage alternating current circuit-breakers
GB/T 7354-2003 Partial discharge measurements
GB/T 7674-2008 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
GB/T 11022-2011 Common specifications for high-voltage switchgear and controlgear standards
GB/Z 24837-2009 Specification for 1100 kV alternating-current disconnectors and earthing switches
IEC 60865-1:1993
IEC 62271-201:2006
GB/T 26218.1-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 1:Definitions,information and general principles
GB/T 26218.2-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 2:Ceramic and glass insulators for a.c.systems
GB/T 26218.3-2011 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 3:Composite insulators for a.c.systems
GB/T 26218.4-2019 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 4:Insulators for d.c. systems
Adopt standards
IEC 62271-102:2001+A1:2011
Related Standards
GB 1984-2003
Replaced
GB 1984-2003 High-voltage alternating-current circuit-breakers
GB 1985-2004
Replaced
GB 1985-2004 High-voltage alternating-current disconnectors and earthing switches
GB/T 4473-2008
Replaced
GB/T 4473-2008 Synthetic testing of High-voltage alternating current circuit-breakers
GB/T 22381-2008
Replaced
GB/T 22381-2008 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above—Fluid-filled and extruded insulation power cables—Fluid-filled and dry type cable-terminations
GB/T 22382-2008
Replaced