GB/T 38693-2020 Active National standards

GB/T 38693-2020 Safety and control devices for gas burners and gas-burning appliances—Particular requirements—Thermoelectric flame supervision controls

GB/T 38693-2020 Safety and control devices for gas burners and gas-burning appliances—Particular requirements—Thermoelectric flame supervision controls

Publish Date: 2020-03-31 Implement Date: 2021-02-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 93
Download

Basic Information

Standard Code: GB/T 38693-2020
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Heating, gas supply, air conditioning, and refrigeration engineering
ICS Name: The facilities in the building
Publish Date: 2020-03-31
Implement Date: 2021-02-01
Pages: 30 pages

Scope

This standard specifies the classification and grouping, structure and materials, requirements, test methods, inspection rules, marking, installation and operation instructions, packaging, transportation, and storage of thermoelectric flameout protection devices (hereinafter referred to as "flameout protection devices") used in urban gas burners and combustion appliances as stipulated in GB/T 13611.
This standard applies to thermoelectric flameout protection devices used in gas burners and combustion appliances with a maximum working pressure not exceeding 500 kPa and a nominal size not exceeding DN50.

Development Information

Word Count: 60 Thousand words Pages: 30 pages

Referenced Standards

Adopt standards

ISO 23551-6:2014

Related Standards

Contact Us