GB/T 9330-2020 Active National standards

GB/T 9330-2020 Plastic insulated control cables

GB/T 9330-2020 Plastic insulated control cables

Publish Date: 2020-03-31 Implement Date: 2020-10-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 9330-2020
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Cable
Publish Date: 2020-03-31
Implement Date: 2020-10-01
Publisher: 国家市场监督管理总局、国家标准化管理委员会
Technical Committee: 全国电线电缆标准化技术委员会(SAC/TC 213)
Pages: 27 pages

Scope

本标准规定了交流额定电压U0/U为450/750 V挤包聚氯乙烯和交联聚乙烯绝缘、聚氯乙烯、聚乙烯和无卤聚烯烃护套控制电缆的产品代号和表示方法、电缆名称和型号规格、成品电缆标志和绝缘线芯识别、技术要求、试验方法和检验规则、使用特性以及包装等。
本标准适用于交流额定电压U0/U为450/750 V及以下控制、监控回路及保护线路等场合固定敷设使用的控制电缆。

Development Information

Drafting Units:

上海国缆检测中心有限公司、宝胜科技创新股份有限公司、扬州曙光电缆股份有限公司、江苏中天科技股份有限公司、江苏亨通线缆科技有限公司、江苏上上电缆集团有限公司、青岛汉缆股份有限公司、远东电缆有限公司、无锡江南电缆有限公司、安徽太平洋电缆股份有限公司、金杯电工股份有限公司、广州南洋电缆有限公司、远程电缆股份有限公司、上海胜华电缆(集团)有限公司、广州电缆厂有限公司、江苏永鼎股份有限公司、昆明电缆集团股份有限公司、海南威特电气集团有限公司、沈阳艾克电缆科技有限公司

Drafting Persons:

杨立志、房权生、梁国华、葛永新、卞凤贤、李斌、曲国安、汪传斌、刘军、王永海、阳文锋、王志辉、章迁平、李小秋、王勋、赵佩杰、习有建、黎驹、苏银玉、郭荣荣、马瞻、何介利、杜青

Word Count: 48 Thousand words Pages: 27 pages

Replace the following standards

Referenced Standards

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 13:Methods for general application—Measurement for determining the density—Water absorption tests—Shrinkage test GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 41:Methods specific to polyethylene and polypropylene compounds—Resistance to environmental stress cracking—Measurement of the melt flow index—Carbon black and/or mineral filler content measurement in polyethylene by direct combustion—Measurement of carbon black content by thermo gravimetric analysis(TGA)—Assessment of carbon black dispersion in polyethylene using a microscope GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires—Part 4:Test of DC resistance of conductors GB/T 3048.5-2007 Test methods for electrical properties of electric cables and wires—Part 5:Test of insulation resistance GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test GB/T 3048.9-2007 Test methods for electrical properties of electric cables and wires—Part 9:Spark test of insulated cores GB/T 3048.10-2007 Test methods for electrical properties of electric cables and wires—Part 10:Spark test of extruded protective sheaths GB/T 3956-2008 Conductors of insulated cables GB/T 4909.2-2009 Test methods for bare wires—Part 2:Measurement of dimensions GB/T 6995.1-2008 Markings for electric wires and cables—Part 1:General requirements GB/T 2900.10-2001 Electrotechnical vocabulary—Electric cables GB/T 2900.10-2013 Electrotechnical terminology—Electric cables GB/T 19666-2005 Flame retardant and fire resistant wires and cables GB/T 19666-2019 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables JB/T 8137.1-1995 JB/T 8137.1-1995 - Specifications for the form and size of delivery racks for electric cables and wires JB/T 8137.1-2013 Wire and Cable Delivery Tray - Part 1: General requirements JB/T 8137.2-1995 JB/T 8137.2-1995 wire and cable delivery disk technical requirements JB/T 8137.2-2013 Wiring Cable Delivery Tray - Part 2: Full Wooden Construction Delivery Tray (English) JB/T 8137.3-2013 Wiring Cable Delivery Tray Part 3: Full Steelcorrugated Delivery Tray JB/T 8137.4-2013 Electric Cable and Wire Delivery Tray - Part 4: Steel Composite Structure Delivery Tray JB/T 8137.1-1999 JB/T 8137.1-1999 Electric wires and cables delivered on a plate - Part 1: General provisions JB/T 8137.2-1999 Wiring Cable Delivery Tray - Part 2: Full Wooden Construction Delivery Tray JB/T 8137.3-1999 Delivery tray for cables and wires - Part 3: Full steel corrugated structure delivery tray JB/T 8137.4-1999 Wiring Harness Delivery Vessel - Part 4: Steel and Composite Structure Delivery Vessels

Related Standards

Contact Us