GB/T 13033.1-2007
Active
National standards
GB/T 13033.1-2007 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V—Part 1:Cables
GB/T 13033.1-2007 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V—Part 1:Cables
Basic Information
Standard Code:
GB/T 13033.1-2007
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Cables and their accessories
ICS Name:
Cable
Publish Date:
2007-01-16
Implement Date:
2007-08-01
Pages:
17 pages
Scope
This part of GB/T 13033 applies to general wiring cables with a rated voltage of 500 V and 750 V, made of copper cores and copper or copper alloy sheaths. If necessary, a layer of anti-corrosive sheath can be extruded outside the copper sheath. The sheath is not used as an electrical insulation for the metal sheath. The requirements for cable terminals are specified in GB/T 13033.2. This part specifies the manufacturing requirements and characteristics to ensure that the mineral insulated cables are safe and reliable when used correctly, and also stipulates the test methods for verifying compliance with these requirements.
Development Information
Same series standard
Replace the following standards
Referenced Standards
GB/T 2951.4-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section four:Test at low temperature
GB/T 2951.6-1997 Common test methods for insulating and sheathing materials of electric cables Part 3:Methods specific to PVC compounds Section one:Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section one:Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 3956-1997 Conductors of insulated cables
GB/T 3956-2008 Conductors of insulated cables
GB 5023.1-1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V—Part 1:General requirements
GB/T 5023.1-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V—Part 1:General requirements
GB/T 13033.2-1991 Mineral insulated cables and their terminations with a rated voltage not exceeding 750V—Part 2:Mineral insulated cables with copper conductors and copper sheath
GB/T 13033.2-2007 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V—Part 2:Terminations
GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity
GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 2:Determination of acidity (by pH measurement) and conductivity
GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions Part 2:Test procedure and requirements
GB/T 17651.2-2021 Measurement of smoke density of cables or optical fiber cables burning under defined conditions—Part 2:Test procedure and requirements
GB/T 18380.1-2001 Tests on electric cables under fire conditions Part 1:Test on a single vertical insulated wire or cable
GB/T 19216.21-2003 Tests for electric cables under fire conditions—Circuit integrity—Part 21:Procedures and requirements—Cable of rated voltage up to and including 0.6/1.0kV
Adopt standards
IEC 60702-1:2002
Related Standards
GB/T 4011-1983
Replaced
GB/T 4012-1983
Replaced
GB/T 4012-1983 2.6/9.5mm composite coaxial cable for telecommunication use
GB/T 5441.10-1985
Replaced
GB/T 5441.10-1985 Test methods for communication cable—Measurement of actual length of coaxial pair—Sine wave method
GB/T 5441.1-1985
Replaced
GB/T 5441.1-1985 Test methods for communication cable General
GB/T 5441.2-1985
Replaced
GB/T 5441.2-1985 Test methods for communication cable Capacitance test Bridge method
GB/T 5441.3-1985
Replaced