GB/T 18380.21-2008 Active National standards

GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions—Part 21:Test for vertical flame propagation for a single small insulated wire or cable—Apparatus

GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions—Part 21:Test for vertical flame propagation for a single small insulated wire or cable—Apparatus

Publish Date: 2008-06-26 Implement Date: 2009-04-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 18380.21-2008
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Cable
Publish Date: 2008-06-26
Implement Date: 2009-04-01
Pages: 7 pages

Scope

This part of GB/T 18380 specifies the equipment for the vertical flame spread test of single insulated fine electrical wires or fine optical cables under flame conditions. The informative appendix of the test method and recommended performance requirements can be found in GB/T 1838022—2008.

Development Information

Word Count: 11 Thousand words Pages: 7 pages

Same series standard

GB/T 18380.11-2008 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame GB/T 18380.13-2008 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles GB/T 18380.22-2008 Tests on electric and optical fibre cables under fire conditions—Part 22:Test for vertical flame propagation for a single small insulated wire or cable—Procedure for diffusion flame GB/T 18380.31-2008 Test on electric and optical fibre cables under fire conditions—Part 31:Test for vertical flame spread of vertically-mounted bunched wires or cables—Apparatus GB/T 18380.32-2008 Tests on electric and optical fibre cables under fire conditions—Part 32:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A F/R GB/T 18380.33-2008 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A GB/T 18380.34-2008 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C GB/T 18380.36-2008 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D

Replace the following standards

Referenced Standards

Adopt standards

IEC 60332-2-1:2004

Related Standards

Contact Us