GB/T 25915.7-2010 Active National standards

GB/T 25915.7-2010 Cleanrooms and associated controlled environments—Part 7:Separative devices (clean air hoods,gloveboxes,isolators and minienvironments)

GB/T 25915.7-2010 Cleanrooms and associated controlled environments—Part 7:Separative devices (clean air hoods,gloveboxes,isolators and minienvironments)

Publish Date: 2011-01-14 Implement Date: 2011-06-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 25915.7-2010
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Industrial dust and gas prevention and control technology
ICS Name: Clean rooms (sterile rooms) and related controlled environments
Publish Date: 2011-01-14
Implement Date: 2011-06-01
Pages: 45 pages

Scope

This part of GB/T 25915 specifies the minimum requirements for the design, construction, installation, testing, and approval of isolation devices, which differ from the requirements for cleanrooms specified in GB/T 25915.4 and GB/T 25915.5.
The application of this part takes into account the following limitations:
—— The user requirements agreed upon by the buyer and the supplier;
—— Specific application requirements not specified in this part;
—— The specific processes to be carried out within the isolation devices are not specified in this part;
—— This part does not pay special attention to mandatory regulations such as fire safety and safety, which should comply with applicable national and local regulations.

Development Information

Word Count: 87 Thousand words Pages: 45 pages

Same series standard

Referenced Standards

Adopt standards

ISO 14644-7:2004

Related Standards