T/SCQA 205-2024 Active Group standards

T/SCQA 205-2024 Applied Technical Specification for Double-plated Lightweight Air-Filled Accreted Concrete Pressure-treated Board

T/SCQA 205-2024 Applied Technical Specification for Double-plated Lightweight Air-Filled Accreted Concrete Pressure-treated Board

Publish Date: 2024-07-01 Implement Date: 2024-07-15 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/SCQA 205-2024
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Building components and equipment
ICS Name: Integrated Building Components
Publish Date: 2024-07-01
Implement Date: 2024-07-15

Scope

Scope: This specification is formulated to ensure the advanced technology, reasonable design, energy conservation, and cost reduction of double-sided walls made of autoclaved aerated lightweight concrete, thereby improving economic and social benefits, ensuring project quality and safety, and preventing potential risks. This document applies to earthquake-resistant areas with a seismic intensity of 8 or lower, and is suitable for the design, construction, and acceptance of new, renovated, and expanded residential, public, and industrial buildings, including exterior and non-load-bearing interior walls. Main technical requirements: - The main materials of double-sided walls should have sufficient compressive and tensile strength to ensure the stability of the overall wall structure, meet the load-bearing requirements of building exterior walls, and comply with relevant provisions of current national standards. - Double-sided walls should meet fire protection requirements and comply with the provisions of the current national standard GB 50016. - Double-sided walls should be integratedly cast with lightweight aggregate concrete and comply with the current industry standard JGJ/T 12. - Special embedded parts, bolts, and window/door frames used in ALC double-sided walls should comply with the relevant provisions of the current national standards GB 50010 and GB 50017. - The waterproof sealant used for TW wall joints should be weather-resistant, compatible with concrete, and have low-temperature resistance, mold resistance, and water resistance. Its maximum expansion deformation, shear deformation performance, and other properties should meet design requirements. Other performance specifications should comply with relevant current standards. - ALC double-sided walls, connection structures, and accessories should be standardized and serialized, and should adopt the principle of fewer specifications and more combinations to meet the requirements of prefab

Development Information

Related Standards

Contact Us