GB/T 16934-1997
Replaced
GB/T 16895.13-2012
Replaced
National standards
GB/T 16895.13-2012 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower
GB/T 16895.13-2012 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower
Basic Information
Standard Code:
GB/T 16895.13-2012
Standard Type:
National standards
Standard Status:
Replaced
is_force_gb:
no
CCS Name:
Building electrical appliances and fire-fighting equipment and devices
ICS Name:
The power supply system
Publish Date:
2012-06-29
Implement Date:
2013-05-01
Pages:
11 pages
Scope
The special requirements of this section apply to electrical installations in places equipped with fixed bathtubs or showers, as well as electrical installations in the surrounding areas described in this section.
This section does not apply to emergency facilities, such as emergency sprinklers used in industrial areas or laboratories.
Development Information
Same series standard
GB/T 16895.5-2012 Low-voltage electrical installations—Part 4-43:Protection for safety—Protection against overcurrent
GB/T 16895.23-2012 Low-voltage electrical installations—Part 6:Verification
GB/T 16895.27-2012 Low-voltage electrical installations—Part 7-705:Requirements for special installations or locations—Agricultural and horticultural premises
Replace the following standards
Superseded by the following standards
Referenced Standards
GB/T 16895.21-2011 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock
GB/T 16895.3-2004 Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment-Earthing arrangements, protective conductors and protective bonding conductors
IEC 61558-2-5
Adopt standards
IEC 60364-7-701:2006(第2版)
Related Standards
GB 16895.5-2000
Replaced
GB 16895.5-2000 Electrical installations of buildings—Part 4:Protection for safety—Chapter 43:Protection against over current
GB 16895.6-2000
Replaced
GB 16895.6-2000 Electrical installations of buildings—Part 5:Selection and erection of electric equipment—Chapter 52:Wiring systems
GB 16895.7-2000
Replaced
GB 16895.7-2000 Electrical installations of buildings Part 7:Requirements for special installations or locations Section 704:Construction and demolition site installations
GB 16895.8-2000
Replaced
GB 16895.8-2000 Electrical installations of buildings—Part 7:Requirements for special installations or location—Section 706:Restrictive conducting locations
GB/T 16895.9-2000
Active