Scope
This standard specifies the usage characteristics, product codes, models, and representation methods, technical requirements, cable markings, and testing and inspection rules for battery connection cables (hereinafter referred to as battery cables) used in power energy storage systems with a maximum voltage level of DC 1,500 V and a maximum continuous operating temperature of 125°C for conductors. This standard applies to cables used between battery modules on the DC side of power energy storage systems, between battery clusters, between battery clusters and junction boxes, and between battery clusters and energy storage converters.
Development Information
Referenced Standards
GB/T 2423.17-2018
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods
GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 13:Methods for general application—Measurement for determining the density—Water absorption tests—Shrinkage test
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test
GB/T 3048.9-2007 Test methods for electrical properties of electric cables and wires—Part 9:Spark test of insulated cores
GB/T 3956-2008 Conductors of insulated cables
GB/T 5013.2-2008 Rubber insulated cables of rated voltages up to and including 450/750 V—Part 2:Test methods
GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V—Part 2:Test methods
GB/T 11026.1-2016 Electrical insulating materials—Thermal endurance properties—Part 1:Ageing procedures and evaluation of test results
GB/T 11026.2-2012 Electrical insulating materials—Thermal endurance properties—Part 2:Choice of test criteria
GB/T 16422.2-2014 Plastics—Methods of exposure to laboratory light sources—Part 2:Xenon-arc sources
GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables Part 1:Determination of the amount of halogen acid gas
GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity
GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions Part 2:Test procedure and requirements
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C
GB/T 18380.36-2008 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D
IEC 60684-2:2011
Related Standards
GB/T 4011-1983
Replaced
GB/T 4012-1983
Replaced
GB/T 4012-1983 2.6/9.5mm composite coaxial cable for telecommunication use
GB/T 5441.10-1985
Replaced
GB/T 5441.10-1985 Test methods for communication cable—Measurement of actual length of coaxial pair—Sine wave method
GB/T 5441.1-1985
Replaced
GB/T 5441.1-1985 Test methods for communication cable General
GB/T 5441.2-1985
Replaced
GB/T 5441.2-1985 Test methods for communication cable Capacitance test Bridge method
GB/T 5441.3-1985
Replaced