GB/T 20975.14-2020 Methods for chemical analysis of aluminium and aluminium alloys—Part 14:Determination of nickel content
GB/T 20975.14-2020 Methods for chemical analysis of aluminium and aluminium alloys—Part 14:Determination of nickel content
Basic Information
Scope
This part of GB/T 20975 specifies the determination of nickel content in aluminum and aluminum alloys by the spectrophotometric method of diketone oxime, the flame atomic absorption spectrometry method, the Na2EDTA titration method, and the diketone oxime gravimetric method.
This part is applicable to the arbitration determination of nickel content in aluminum and aluminum alloys. The determination range of the spectrophotometric method of diketone oxime is 0.001% to 0.010%; the determination range of the flame atomic absorption spectrometry method is 0.005% to 3.00%; the determination range of the Na2EDTA titration method is 5.00% to 25.00%; and the determination range of the diketone oxime gravimetric method is 5.00% to 30.00%.
Note: When the nickel mass fraction is > 0.005% to 0.010%, the flame atomic absorption spectrometry method is used as the arbitration method; when the nickel mass fraction is 5.00% to 25.00%, the Na2EDTA titration method is used as the arbitration method.