GB/T 12706.1-2008 Replaced National standards

GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)

GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)

Publish Date: 2008-12-31 Implement Date: 2009-11-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 12706.1-2008
Standard Type: National standards
Standard Status: Replaced
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Cable
Publish Date: 2008-12-31
Implement Date: 2009-11-01
Pages: 42 pages

Scope

This part of GB/T 12706 specifies the structure, dimensions, and test requirements of fixed-installation extruded insulated power cables with a rated voltage of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV) used in distribution networks or industrial installations.
This part includes flame-retardant, low-smoke, and halogen-free cables.
This part does not include cables intended for special installation and operating conditions, such as those used in overhead lines, the mining industry, nuclear power plants (inside and near the containment vessel), and underwater or shipboard applications.

Development Information

Word Count: 77 Thousand words Pages: 42 pages

Same series standard

Replace the following standards

Superseded by the following standards

Referenced Standards

GB/T 156-2007 Standard voltages GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 13:Methods for general application—Measurement for determining the density—Water absorption tests—Shrinkage test GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 41:Methods specific to polyethylene and polypropylene compounds—Resistance to environmental stress cracking—Measurement of the melt flow index—Carbon black and/or mineral filler content measurement in polyethylene by direct combustion—Measurement of carbon black content by thermo gravimetric analysis(TGA)—Assessment of carbon black dispersion in polyethylene using a microscope GB/T 3048.10-2007 Test methods for electrical properties of electric cables and wires—Part 10:Spark test of extruded protective sheaths GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires—Part 13:Impulse voltage test GB/T 3956-2008 Conductors of insulated cables GB/T 6995.3-2008 Markings for electric wires and cables—Part 3:Identifications of cables and wires GB/T 6995.5-2008 Markings for electric wires and cables—Part 5:Identifications of insulated cores of power cables GB/T 11091-2005 Copper strips for cables GB/T 12706.2-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2:Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV) GB/T 16927.1-1997 High-voltage test techniques Part 1:General test requirements GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables Part 1:Determination of the amount of halogen acid gas GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions Part 2:Test procedure and requirements GB/T 18380.11-2008 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame GB/T 18380.13-2008 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C GB/T 19666-2005 Flame retardant and fire resistant wires and cables JB/T 8137-1999(所有部分) ISO 48:2007 IEC 60684-2:2003 IEC 60724:2000 JB/T 8996-1999 JB/T 8996-1999 High-voltage cable selection guidelines YB/T 024-2008 Steel strips for cable armouring

Adopt standards

IEC 60502-1:2004

Related Standards