GB/T 18494.2-2007 Convertor transformers—Part 2:Transformers for HVDC applications
GB/T 18494.2-2007 Convertor transformers—Part 2:Transformers for HVDC applications
Basic Information
Standard Code:
GB/T 18494.2-2007
Standard Type:
National standards
Standard Status:
Replaced
is_force_gb:
no
CCS Name:
Transformer
ICS Name:
Transformers, reactors, and inductors
Publish Date:
2007-01-16
Implement Date:
2007-08-01
Pages:
17 pages
Scope
This part of GB/T 18494 is applicable to three-phase and single-phase oil-immersed converter transformers used in high-voltage direct current (HVDC) transmission systems with two, three, or more windings. This part is not applicable to: — industrial converter transformers; — traction converter transformers.
Development Information
Superseded by the following standards
Referenced Standards
GB/T 2900.15-1997 Electrotechnical terminology Transformer, instrument transformer, voltage regulator and reactor
GB/T 2900.33-2004 Electrotechnical terminoligy—Power electronics
GB/T 3859.1-1993 Semiconductor convertors—Specification of basic requirements
GB/T 3859.2-1993 Semiconductor convertors—Application guide
GB/T 7354-2003 Partial discharge measurements
GB/T 13499-2002 Power transformers—Application guide
GB/T 15164-1994 Loading guide for oil-immersed power transformers
GB/T 17623-1998 Determination of componental contents of gases dissolved in insulating oil by gas chromatography method
GB/T 18494.1-2001 Convertor transformers—Part 1:Transformers for industrial applications
GB 1094.1-1996 Power transformers—Part 1:General
GB/T 1094.1-2013 Power transformers—Part 1:General
GB 1094.2-1996 Power transformers—Part 2:Temperature rise
GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers
GB/T 1094.3-2003 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB 1094.5-2003 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.5-2008 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.10-2003 Power transformers—Part10:Determination of sound levels
GB/T 1094.10-2022 Power transformers—Part 10:Determination of sound levels
GB/T 4109-1999 Technical specification of high voltage bushing
GB/T 4109-2008 Insulated bushings for alternating voltages above 1 000 V
GB/T 4109-2022 Insulated bushings for alternating voltages above 1 000 V
GB/T 10230.1-2007 Tap-changers—Part 1:Performance requirements and test methods
GB/T 10230.1-2019 Tap-changers—Part 1:Performance requirements and test methods
GB/T 10230.2-2007 Tap-changers—Part 2:Application guide
GB/T 10230.2-2025 Tap changers—Part 2:Application guidelines
Adopt standards
IEC 61378-2:2001
Related Standards
GB/T 7449-1987
Replaced
GB/T 7449-1987 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
GB 13028-1991
Abolished
GB 13028-1991 Isolating transformers and safety isolating transformers Requirements
GB/T 14006-1992
Active
GB/T 14006-1992 Outline dimensions of transformers and inductors for use in telecommunication and electronic equipment—Part 1:Transformers and inductors using YEI-1 laminations
GB/T 14860-1993
Replaced
GB/T 14860-1993 Generic specification for transformers and inductors for use in telecommunication and electronic equipment
GB/T 15164-1994
Replaced