GB/T 18380.32-2022 Active National standards

GB/T 18380.32-2022 Tests on electric and optical fibre cables under fire conditions—Part 32:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A F/R

GB/T 18380.32-2022 Tests on electric and optical fibre cables under fire conditions—Part 32:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A F/R

Publish Date: 2022-04-15 Implement Date: 2022-11-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 54
Download

Basic Information

Standard Code: GB/T 18380.32-2022
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Cable
Publish Date: 2022-04-15
Implement Date: 2022-11-01
Pages: 12 pages

Scope

This document describes the A F/R class test method used to evaluate the ability of vertically installed bundled wires and cables to suppress the vertical spread of flames under specified conditions. This document is applicable to power cables with a conductor cross-section greater than 35 mm2, which are installed intermittently in front and behind the test steel ladder to achieve a total nominal volume of 7 L/m for the non-metallic materials contained in the specimens. The fire supply time is 40 minutes. This installation method is used for special cables required to be used in special devices in the cable specifications. The A F/R class is not suitable for ordinary cables. This test is used for type approval testing. The selection requirements for test cables are described in Appendix A. The spread of flames is measured by the damage range of the cable specimens. This test procedure can be used to verify the ability of cables to suppress the spread of flames. The recommended performance requirements are given in Appendix B. Note: In this document, the term "wires and cables" includes all metal conductor insulated cables used for power or signal transmission.

Development Information

Word Count: 25 Thousand words Pages: 12 pages

Same series standard

GB/T 18380.11-2022 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus GB/T 18380.12-2022 Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame GB/T 18380.13-2022 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles GB/T 18380.31-2022 Tests on electric and optical fibre cables under fire conditions—Part 31:Test for vertical flame spread of vertically-mounted bunched wires or cables—Apparatus GB/T 18380.33-2022 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A GB/T 18380.34-2022 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B GB/T 18380.35-2022 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mountedbunched wires or cables—Category C GB/T 18380.36-2022 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D

Replace the following standards

Referenced Standards

IEC 60332-3-10 IEC 60811-606

Adopt standards

IEC 60332-3-21:2018

Related Standards

Contact Us