YY 0600.3-2007 Replaced Industry standards-Medicine

YY 0600.3-2007 Lung ventilators for medical use—Particular requirements for basic safety and essential performance—Part 3:Emergency and transport ventilators

YY 0600.3-2007 Lung ventilators for medical use—Particular requirements for basic safety and essential performance—Part 3:Emergency and transport ventilators

Publish Date: 2007-01-31 Implement Date: 2008-02-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: YY 0600.3-2007
Standard Type: Industry standards
Standard Status: Replaced
is_force_gb: no
CCS Name: Surgical room equipment
ICS Name: Anesthesia, respiration, and resuscitation equipment
Publish Date: 2007-01-31
Implement Date: 2008-02-01
Pages: 28 pages

Scope

Note: See the explanations in Appendix AA. This part is a dedicated standard based on GB 9706.1 "Medical Electrical Equipment - Part 1: General Safety Requirements". As stated in GB 9706.1 1.3, the requirements of this part are more stringent than those of GB 9706.1. If a clause of GB 9706.1 is stated to be applicable in this part, it means that the clause is only applicable when the requirements put forward are related to the emergency and transfer use of respirators. This part shares common requirements with GB 9706.28 "Medical Electrical Equipment - Part 2: Safety Requirements for Respirators for Therapeutic Use". The scope of application and purpose given in Chapter 1 of GB 9706.1 - 2007 are applicable, but 1.1 should be modified as follows: This part specifies the requirements for portable respirators used in emergencies and during patient transport. Emergency and transfer portable respirators (hereinafter referred to as "respirators") are often installed in ambulances or other rescue vehicles, but are also often used outside vehicles and must be carried by operators or other personnel. These devices are often used by personnel with varying degrees of training outside hospitals or at home. This part is also applicable to respirators that are fixedly installed in ambulances or airplanes. The content of this part does not apply to artificial respirators (such as artificial resuscitators).

Development Information

Word Count: 47 Thousand words Pages: 28 pages

Same series standard

Superseded by the following standards

Referenced Standards

GB/T 2423.6-1995 Environmental testing for electric and electronic products—Part 2:Test methods—Test Eb and guidance:Bump GB/T 2423.8-1995 Environmental testing for electric and electronic products—Parts 2:Test methods—Test Ed:Free fall GB/T 2423.10-1995 Environmental testing for electric and electronic products—Part 2:Test methods—Test Fc and guidance:Vibration (Sinusoidal) GB/T 4999-2003 Anaesthetic and respiratory equipment—Vocabulary GB/T 5332-1985 Method of test for ignition temperature of flammable liquids and gases GB 7144-1999 Colored cylinder mark for gases GB 9706.1-1995 Medical electrical equipment—Part 1:General requirements for safety GB 9706.1-2007 Medical electrical equipment—Part 1:General requirements for safety GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance GB 9706.28-2006 Medical electrical equipment—Part 2:Particular requirements for the safety of lung ventilators—Critical care ventilators YY/T 0461-2003 Breathing tubes intended for use with aneasthetic apparatus and ventilators YY 0505-2005 Medical electrical equipment—Part 1-2:General requirements for safety—Collateral standard:Electromagnetic compatibility—Requirements and tests YY 0574.1-2005 Anaesthesia and respiratory care alarm signals—Part 1:Visual alarm signals YY 0574.2-2005 Anaesthesia and respiratory care alarm signals—Part 2:Auditory alarm signal YY 1040.1-2003 Anaesthetic and respiratory equipment—Conical connectors—Part 1:Cones and sockets ISO 5356-2:1987 ISO 5359:1989 ISO 5362:1986 ISO 9170:1990 IEC 68-2-36

Adopt standards

ISO 10651-3:1997