NB/T 11456-2023 Technical specification for cleaner production of coal preparation plant
本文件规定了选煤厂清洁生产的基本要求、基本原则、生产系统要求、设备技术要求、技术经济指标要求、污染物排放要求、监测与指标计算。
本文件适用于选煤厂技术经济指标评价、清洁生产技术改造以及各项管理制度制定。
Current Category: CN-NB - Energy
本文件规定了选煤厂清洁生产的基本要求、基本原则、生产系统要求、设备技术要求、技术经济指标要求、污染物排放要求、监测与指标计算。
本文件适用于选煤厂技术经济指标评价、清洁生产技术改造以及各项管理制度制定。
This document stipulates the technical requirements for the overall construction of intelligent new energy power stations, system setup, intelligent sensing construction, integrated platform construction, and security protection. This document is applicable to the intelligent construction of wind power and photovoltaic power stations. Other types of new energy power stations can refer to it for guidance in their intelligent construction.
This document specifies the testing purposes, testing conditions, testing content, and acceptance criteria for the commissioning of the high-pressure hydrogen system in nuclear power plants. This document is applicable to the commissioning tests of the high-pressure hydrogen system in nuclear power plants.
This document specifies the test conditions, testing equipment, test preparation, test steps, result determination, and test report requirements for the curling test of flexible film photovoltaic modules in photovoltaic power stations. This document is applicable to the curling performance test of flexible film photovoltaic modules in photovoltaic power stations, and the curling performance test of flexible crystalline silicon photovoltaic modules can be used as a reference.
This document specifies the test conditions, test equipment, test preparation, test steps, result determination, and test reports for the tensile testing of flexible film photovoltaic modules in photovoltaic power stations. This document is applicable to the tensile performance testing of flexible film photovoltaic modules in photovoltaic power stations, and the tensile performance testing of flexible crystalline silicon photovoltaic modules can be used as a reference.
This document specifies the test conditions, testing equipment, test preparation, test steps, result determination, and test reports for the vibration testing of flexible thin-film photovoltaic modules in photovoltaic power stations. This document is applicable to the vibration performance testing of flexible thin-film photovoltaic modules in photovoltaic power stations, and the vibration performance testing of flexible crystalline silicon photovoltaic modules can be used as a reference.
This document specifies the test conditions, testing equipment, testing steps, result determination, and test report requirements for the indentation test of flexible thin-film photovoltaic modules in photovoltaic power stations. This document is applicable to the mechanical performance test of flexible thin-film photovoltaic modules.
This document stipulates the general requirements for the evaluation of the utilization rate of photovoltaic power generation resources, including data collection, calculation of utilization rate, and analysis and evaluation. This document is applicable to new, renovated, and expanded photovoltaic power stations that are connected to the grid at a voltage level of 10kV or higher. Photovoltaic power stations equipped with energy storage systems may refer to and implement this document accordingly.
This document specifies the technical requirements for simulation modeling, impedance analysis, simulation analysis, and comprehensive evaluation in the assessment of the impedance characteristics of photovoltaic power stations. This document is applicable to the assessment of the impedance characteristics of new, modified, and expanded photovoltaic power stations that are connected to the grid at a voltage level of more than 10 kV. Photovoltaic power stations equipped with energy storage systems can refer to and implement this document accordingly.
This document stipulates the requirements for photovoltaic arrays, power collection lines, substations, internal roads, fire-fighting facilities, and the setting up of safety signs and safety warning lines in photovoltaic power stations. This document applies to the setting up of safety signs during the construction and operation of photovoltaic power stations.
This document specifies the technical requirements for the maintenance of photovoltaic arrays, inverters, on-site step-up transformers, collection lines, energy storage systems, and other components of photovoltaic power stations. This document is applicable to the maintenance of photovoltaic power station equipment.
This document stipulates the general requirements for the production and operation centers of power generation enterprises to access photovoltaic power generation data, as well as the technical requirements for data transmission, data encoding, data governance, storage, and security. This document is applicable to the access of photovoltaic power generation data by the production and operation centers of power generation enterprises.