GB/T 15543-1995
Replaced
GB/T 37012-2018
Active
National standards
GB/T 37012-2018 Technical specification of earthing equipment for high-voltage direct current(HVDC) transmission using voltage sourced converters(VSC)
GB/T 37012-2018 Technical specification of earthing equipment for high-voltage direct current(HVDC) transmission using voltage sourced converters(VSC)
Basic Information
Standard Code:
GB/T 37012-2018
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
The power system
ICS Name:
The integrated transmission and distribution network
Publish Date:
2018-12-28
Implement Date:
2019-07-01
Pages:
26 pages
Scope
This standard specifies the usage conditions of grounding equipment for flexible DC transmission systems, the performance requirements of various grounding devices such as the neutral point grounding resistors in coupling transformers, DC-side grounding resistors, star-connected reactors for grounding equipment, and grounding transformers, as well as the test items and markings, packaging, transportation, and storage of these devices. This standard applies to grounding equipment for symmetric single-pole modular multi-level topology flexible DC transmission systems with a DC voltage of ±500 kV or lower.
Development Information
Referenced Standards
GB/T 311.1-2012 Insulation co-ordination—Part 1:Definitions,principles and rules
GB/T 1094.1-2013 Power transformers—Part 1:General
GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers
GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 1094.4-2005 Power transformers—Part 4:Guide to the lightning impulse and switching impulse testing—Power transformers and reactors
GB/T 1094.5-2008 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.6-2011 Power transformers—Part 6:Reactors
GB/T 1094.10-2003 Power transformers—Part10:Determination of sound levels
GB/T 1094.11-2007 Power transformers—Part 11:Dry-type transformers
GB/T 1094.18-2016 Power transformers—Part 18:Measurement of frequency response
GB/T 2423.1-2008 Environmental testing for electric and electronic products—Part 2:Test methods—Tests A:Cold
GB 2536-2011 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
GB/T 4109-2008 Insulated bushings for alternating voltages above 1 000 V
GB/T 16927.1-2011 High-voltage test techniques—Part 1:General definitions and test requirements
GB/T 20840.1-2010 Instrument transformers—Part 1:General requirements
GB/T 20840.3-2013 Instrument transformers—Part 3:Additional requirements for inductive voltage transformers
GB/T 30547-2014 Filter resistor for high voltage direct current(HVDC) transmission system
GB/T 5273-1985 Terminals for transformers,high-voltage apparatus and bushings
GB/T 5273-2016 Dimensional standardisation of terminals for high-voltage apparatus
GB/T 6451-1999 Specification and technical requirements for three-phase oil-immersed power transformers
GB/T 6451-2008 Specification and technical requirements for oil-immersed power transformers
GB/T 6451-2015 Specification and technical requirements for oil-immersd power transformers
GB/T 6451-2023 Technical parameters and requirements for oil-immersed power transformers
GB 8287.1-1998 High voltage post insulators of ceramic material Part 1:Technical specification
GB/T 8287.1-2008 Indoor and outdoor post insulators for systems with nominal voltage greater than 1 000 V—Part 1:Test on insulators of ceramic material or glass
GB/T 8287.2-1999 High voltage post insulators of ceramic material—Part 2:Dimensions and characteristics
GB/T 8287.2-2008 Indoor and outdoor post insulators for systems with nominal voltage greater than 1 000 V—Part 2:Dimensions and characteristics
GB/T 10228-1997 Specification and technical requirements for dry-type power transformers
GB/T 10228-2008 Specification and technical requirements for dry-type power transformers
GB/T 10228-2015 Specification and technical requirements for dry-type power transformers
GB/T 10228-2023 Technical parameters and requirements for dry-type power transformers
GB/T 26218.1-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 1:Definitions,information and general principles
DL/T 722-2014 Guidelines for analyzing and evaluating the dissolved gases in transformer oil
DL/T 1048-2021 Electric power system support composite insulator - Definition, testing methods and acceptance criteria
DL/T 1048-2007 AC Type Composite Insulator for use at Voltages Above 1000V with Nominal Voltage - Definition, Test Methods and Acceptance Criteria
Related Standards
GB/T 15544-1995
Replaced
GB/T 15544-1995 Short-circuit current calculation in three-phase a.c. systems
GB/T 18857-2002
Replaced
GB/T 18857-2002 Technical guide for live working in distribution line
GB/T 13730-2002
Active
GB/T 13730-2002 Dispatching automation systems for distric power networks
GB/T 2694-2003
Replaced
GB/T 2694-2003 Transmission line tower—Technical requirements for manufacturing
GB/T 11920-2008
Active