GB/T 25996-2019 Active National standards

GB/T 25996-2019 Test method for thermal insulations on external stress corrosion cracking of austenitic stainless steel

GB/T 25996-2019 Test method for thermal insulations on external stress corrosion cracking of austenitic stainless steel

Publish Date: 2019-10-18 Implement Date: 2020-09-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 50
Download

Basic Information

Standard Code: GB/T 25996-2019
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Insulation, sound-absorbing, lightweight, and fire-resistant materials
ICS Name: The insulation of buildings
Publish Date: 2019-10-18
Implement Date: 2020-09-01
Pages: 11 pages

Scope

1.1 This standard specifies the terms and definitions, instruments and equipment, reagents and materials, preparation of stainless steel specimens, preparation of insulation material specimens, test methods, verification of the qualified stainless steel specimens sensitized for the test, inspection of stainless steel specimens after the test, test results, and test reports for the test method of external stress corrosion cracking of austenitic stainless steel by insulation materials.
1.2 This standard is applicable to insulation materials and products used for austenitic stainless steel, including mineral wool, calcium silicate, composite silicates, expanded perlite, foam asbestos, foam glass, aerogels, and insulating and fire-resistant coatings. It is also applicable to cement and adhesives.
1.3 This standard provides two test methods: the Dana method and the drip method, with the following applicability:
——The Dana method is only applicable to capillary-absorbing materials, and the drip method is applicable to all materials that can be cut or molded into test specimens;
——When the material can be heat-treated into capillary-absorbing materials, it can be tested by the Dana method or the drip method;
——When the material cannot be processed into capillary-absorbing materials or the heat-treatment temperature is higher than the manufacturer's recommended temperature, it shall be tested by the drip method.

Development Information

Word Count: 20 Thousand words Pages: 11 pages

Replace the following standards

Referenced Standards

Related Standards