GB/T 12667-1990
Replaced
GB/T 22722-2008
Abolished
National standards
GB/T 22722-2008 Specification for YX3 series(IP55)high efficiency three-phase induction motor(frame size 80~355)
GB/T 22722-2008 Specification for YX3 series(IP55)high efficiency three-phase induction motor(frame size 80~355)
Basic Information
Standard Code:
GB/T 22722-2008
Standard Type:
National standards
Standard Status:
Abolished
is_force_gb:
no
CCS Name:
Rotating motor
ICS Name:
Electric motor
Publish Date:
2008-12-30
Implement Date:
2009-10-01
Pages:
30 pages
Scope
This standard specifies the types, basic parameters, and dimensions of the YX3 series high-efficiency electric motors, technical requirements, inspection rules, marking, packaging, and warranty period requirements.
This standard applies to YX3 series (IP55) high-efficiency three-phase asynchronous electric motors (frame sizes 80~355) (hereinafter referred to as electric motors). All electric motors derived from this series can also be implemented in accordance with this standard.
Development Information
Referenced Standards
GB/T 191-2008 Packaging—Pictorial marking for handling of goods
GB/T 755-2008 Rotating electrical machines—Rating and performance
GB/T 997-2008 Rotating electrical machines—Classification of types of construction,mounting arrangements and terminal box position for(IM Code)
GB/T 1032-2005 Test procedures for three-phase induction motors
GB/T 1971-2006 Rotating electrical machines—Terminal markings and direction of rotation
GB/T 1993-1993 Cooling methods for rotating electrical machines
GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines—Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1080
GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machined(IP code)—Classification
GB/T 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher—Measurement,evaluation and limits of vibration severity
GB/T 10069.1-2006 Measurement of the airborne noise emitted by rotating electrical machines and the noise limits—Part 1:Method for the measurement of airborne noise emitted by rotating electrical machines
GB/T 12665-2008 Requirements of damp-heat testing of electrical machine for service in general environmental condition
GB 14711-2006 Safety requirements of small and medium size rotating electrical machines
GB 18613-2006 Minimum allowable values of energy efficiency and the energy efficiency grades for small and medium three-phase asynchronous motors
JB/T 9615.2-2000 The inter-turn insulation test limit value for the loose-wound winding of low-voltage motors
JB/T 9615.1-2000 Test Method for Inter-Winding Insulation of AC Low-Voltage Motors with Embedded and Wrapped Windings
Related Standards
GB/T 12974-1991
Replaced
GB/T 12974-1991 General specification for a.c. lift motors
GB/T 13138-1991
Replaced
GB/T 13138-1991 Synchros General specification for
GB/T 13139-1991
Replaced
GB/T 13139-1991 Hysteresis synchronous motors General specification for
GB/T 13500-1992
abolished_transferred
GB/T 13500-1992 Three phase asynchronous motors for hermetic refrigeration compressors—General specifications
GB/T 13501-1992
Replaced