GB 12662-1990
Replaced
GA/T 1297-2016
Abolished
Industry standards-Public safety
GA/T 1297-2016 Wires and cables for security systems
GA/T 1297-2016 Wires and cables for security systems
Basic Information
Standard Code:
GA/T 1297-2016
Standard Type:
Industry standards
Standard Status:
Abolished
is_force_gb:
no
CCS Name:
Security and Alarm System
ICS Name:
Crime prevention
Publish Date:
2016-07-08
Implement Date:
2016-08-01
Pages:
53 pages
Scope
This standard specifies the classification and marking of security cables, technical requirements, marking, manufacturing length, test methods, inspection rules, packaging, transportation, and storage, etc.
This standard applies to cables used in intrusion alarm systems, video surveillance systems, access control systems, explosion-proof safety inspection systems, and security prevention systems composed or integrated by these systems.
Development Information
Superseded by the following standards
Referenced Standards
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test
GB/T 2951.42-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 42:Methods specific to polyethylene and polypropylene compounds—Tensile strength and elongation at break after conditioning at elevated temperature—Wrapping test after conditioning at elevated temperature—Wrapping test after thermal ageing in air—Measurement of mass increase—Long-term stability test—Test method for copper-catalyzed oxidative degradation
GB/T 3048.4-1994 Test methods for determining electrical properties of electric cables and wires Measurement of D.C. resistance of conductors
GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires—Part 4:Test of DC resistance of conductors
GB/T 3048.4-2025 Test methods for electrical properties of electric cables and wires—Part 4:Test of DC resistance of conductors
GB/T 3048.8-1994 Test methods for determining electrical properties of electric cables and wires A.C. voltage tests
GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test
GB/T 3048.8-2025 Test methods for electrical properties of electric cables and wires— Part 8:AC voltage test
GB/T 3953-2009 Round copper wire for electrical purposes
GB/T 3953-2024 Round copper wire for electrical purposes
GB/T 4910-1985 Tinned round copper wire
GB/T 4910-2009 Tinned round copper wire
GB/T 4910-2022 Tinned round copper wire
GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V—Part 2:Test methods
GB/T 8815-2002 Plasticized polyvinyl chloride (PVC) compounds for wire and cable
GB/T 8815-2008 Plasticized polyvinyl chloride(PVC)compounds for wire and cable
GB/T 14864-2013 Solid-polyethene insulated flexible radio-frequency cables
GB/T 16422.3-1997 Plastics—Methods of exposure to laboratory light sources—Part 3:Fluorescent UV lamps
GB/T 16422.3-2014 Plastics—Methods of exposure to laboratory light sources—Part 3:Fluorescent UV lamps
GB/T 16422.3-2022 Plastics—Methods of exposure to laboratory light sources—Part 3:Fluorescent UV lamps
GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity
GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 2:Determination of acidity (by pH measurement) and conductivity
GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions Part 2:Test procedure and requirements
GB/T 17651.2-2021 Measurement of smoke density of cables or optical fiber cables burning under defined conditions—Part 2:Test procedure and requirements
GB/T 18015.1-2007 Multicore and symmetrical pair/quad cables for digital communications—Part 1:Generic specification
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.12-2022 Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.33-2008 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.33-2022 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.34-2008 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.34-2022 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C
GB/T 18380.35-2022 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mountedbunched wires or cables—Category C
GB/T 19216.21-2003 Tests for electric cables under fire conditions—Circuit integrity—Part 21:Procedures and requirements—Cable of rated voltage up to and including 0.6/1.0kV
GB/T 19216.23-2003 Tests for electric cables under fire conditions—Circuit integrity—Part 23:Procedures and requirements—Electric data cables
GB/T 19666-2005 Flame retardant and fire resistant wires and cables
GB 50348-2004
GY/T 135-1998 The technical specification and measurement methods for the networking of coaxial cables with physical foam-filled polyvinyl chloride insulation in cable television systems
JB/T 10696.2-2007 Test methods for mechanical and physical properties of wires and cables - Part 2: Flexure test for soft wires and cables
JB/T 10696.9-2011 JBT 10696.9-2011 Test methods for mechanical and physical properties of wires and cables Part 9: Termite test for wires and cables
JB/T 10696.10-2011 Test methods for determing mechanical,physical and chemical properties of electric cables and wires-Part 10:Rat gnawing test
YD/T 760-2023 Communication cable polyolefin insulated material
YD/T 769-2018 Communication center tube filled outdoor optical cable
YD/T 769-2010 Outdoor optical cable for center tube communication
YD/T 769-2003 Core network optical cable - Center tube outdoor communication optical cable
YD/T 901-2018 Communication Layer-twisted Fill Outdoor Optical Cable
YD/T 901-2009 Layered splicing outdoor optical cable for communication
YD/T 1019-2013 Digital communication cable with polyolefin insulated level and twisted pair
YD/T 1020.1-2021 Antiparasite protective sleeve material characteristics for cables and optical fibers - Part 1: Polyamide
YD/T 1020.1-2004 Antiprismatical material characteristics for cable and optical fiber protection sleeves Part 1: Polyamide
YD/T 1020.2-2004 Characteristics of termite resistant jacketing materials for electrical cable and optical cable Part 2:polyolefin copolymer
YD/T 1258.1-2015 Indoor optical cables - Part 1: General principles
YD/T 1258.1-2003 Indoor optical cables series Part 1: General principles
YD/T 1258.1-2025 Indoor optical cables - Part 1: General specifications
YD/T 1258.2-2009 Indoor Light Cables Series Part 2: Single-core and Double-core Light Cables for Terminal Light Cables Component
YD/T 1258.2-2003 Indoor optical cables series - Part 2: Single-core optical cables
YD/T 1258.2-2025 Indoor optical cables - Part 2: Single- and double-core optical cables for terminal components
YD/T 1258.3-2009 Indoor optical cables series Part 3: Single and dual core optical cables for residential wiring
YD/T 1258.3-2003 Indoor optical cable series - Part 3: Double-core optical cable
YD/T 1258.3-2025 Indoor optical fiber, Part 3: Single-core and double-core optical cables for house wiring
YD/T 1997.1-2022 Communication-Introduction of optical cables - Part 1: Butterfly optical cables
YD/T 1997.1-2014 Communication-Introduction of optical cables - Part 1: Butterfly optical cables
YD/T 2488-2013 Flexible steel armored optical cable
YD/T 2488.1-2023 Flexible Steel Quad Stranded Optical Cable - Part 1: Round Optical Cables
YD/T 2488.2-2023 Flexible Steel Conductor Covered Optical Fiber Cable - Part 2: Butterfly Optical Fiber Cable
IEC 60189-1:2007
IEC 61196-1-302:2008
Related Standards
GB 12899-1991
Replaced
GB 12899-1991 Specification for hand-held metal detectors
GB 15407-1994
Replaced
GB 15407-1994 Performance criteria and test methods for microwave interruption intrusion detector
GB 10408.7-1996
Abolished
GB 10408.7-1996 Combination ultrasonic & passive infrared intrusion detector
GB/T 16571-1996
Replaced
GB/T 16571-1996 Designed criterion of security and alarm engineering for cultural museums series
GB/T 16676-1996
Replaced