GB/T 25302-2010 Active National standards

GB/T 25302-2010 Specification for high efficiency three-phase induction motor for textile purpose(Frame size 90~225)

GB/T 25302-2010 Specification for high efficiency three-phase induction motor for textile purpose(Frame size 90~225)

Publish Date: 2010-11-10 Implement Date: 2011-05-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 25302-2010
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Asynchronous motor
ICS Name: Electric motor
Publish Date: 2010-11-10
Implement Date: 2011-05-01
Pages: 25 pages

Scope

This standard specifies the types, basic parameters and dimensions, technical requirements, inspection rules, as well as the requirements for marking, packaging, and warranty period of high-efficiency three-phase asynchronous motors specifically designed for textile applications (hereinafter referred to as "motors").
This standard applies to high-efficiency three-phase asynchronous motors specifically designed for textile applications (with a base number of 90 to 225). The motors have a more effective anti-fiber clogging capability and higher overload capacity than general motors, making them particularly suitable for use in short-fiber environments. The motors are suitable for operation under normal temperature and humidity conditions in textile workshops. All other types of motors derived from this series of motors can also be implemented in accordance with this standard.

Development Information

Word Count: 42 Thousand words Pages: 25 pages

Referenced Standards

GB/T 191-2008 Packaging—Pictorial marking for handling of goods GB/T 755-2008 Rotating electrical machines—Rating and performance GB/T 997-2008 Rotating electrical machines—Classification of types of construction,mounting arrangements and terminal box position for(IM Code) GB/T 1032-2005 Test procedures for three-phase induction motors GB/T 1971-2006 Rotating electrical machines—Terminal markings and direction of rotation GB/T 1993-1993 Cooling methods for rotating electrical machines GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines—Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1080 GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machined(IP code)—Classification GB/T 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher—Measurement,evaluation and limits of vibration severity GB/T 10069.1-2006 Measurement of the airborne noise emitted by rotating electrical machines and the noise limits—Part 1:Method for the measurement of airborne noise emitted by rotating electrical machines GB/T 12665-2008 Requirements of damp-heat testing of electrical machine for service in general environmental condition GB 14711-2006 Safety requirements of small and medium size rotating electrical machines GB/T 22719.1-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines—Part 1:Test methods GB/T 22719.2-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines—Part 2:Test limits

Related Standards

Contact Us