GB/T 4011-1983
Replaced
GB/T 12706.2-2020
Active
National standards
GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2:Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2:Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
Basic Information
Standard Code:
GB/T 12706.2-2020
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Cables and their accessories
ICS Name:
Cable
Publish Date:
2020-03-31
Implement Date:
2020-10-01
Publisher:
国家市场监督管理总局、国家标准化管理委员会
Technical Committee:
全国电线电缆标准化技术委员会(SAC/TC 213)
Pages:
66 pages
Scope
GB/T 12706的本部分规定了额定电压6 kV到30 kV挤包绝缘电力电缆的结构、尺寸和试验要求。
本部分适用于配电网或工业装置中固定安装的额定电压6 kV到30 kV挤包绝缘电力电缆。本部分也适用于纵向阻水结构电缆及其试验。在决定电缆应用时,宜考虑径向进水的可能风险。
本部分不适用于特殊安装和运行条件的电缆,例如架空电缆、采矿工业、核电厂(安全壳内及其附近),以及水下或船舶的电缆。
Development Information
Drafting Units:
上海电缆研究所有限公司、中国电力科学研究院、上海国缆检测中心有限公司、宝胜科技创新股份有限公司、江苏上上电缆集团有限公司、远东电缆有限公司、无锡江南电缆有限公司、中天科技海缆有限公司、浙江万马股份有限公司、杭州电缆股份有限公司、江苏亨通电力电缆有限公司、青岛汉缆股份有限公司、金杯电工股份有限公司、广州南洋电缆有限公司、福建南平太阳电缆股份有限公司、上海华普电缆有限公司、宁波球冠电缆股份有限公司、昆明电缆集团股份有限公司、杭州华新电力线缆有限公司、上海飞航电线电缆有限公司、郑州华力电缆有限公司、扬州曙光电缆股份有限公司、乐星红旗电缆(湖北)有限公司、海南威特电气集团有限公司等
Drafting Persons:
孙建生、赵健康、贺金红、房权生、李斌、汪传斌、刘军、谢书鸿、刘焕新、滕兆丰、管新元、王野、阳文锋、王志辉、范德发、周雁、温尚海、习有建、郭海军、胡少中、赵红燕、梁国华、王柏译、黎驹、魏永乾、陈伟、李忠、施楠楠、朱涛、杜青
Same series standard
GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 3:Cables for rated voltages of 35 kV(Um=40.5 kV)
GB/T 12706.4-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 4:Test requirements on accessories for cables with rated voltages from 6 kV(Um=7.2 kV)up to 35 kV(Um=40.5 kV)
Replace the following standards
Referenced Standards
GB 156-2003 Standard voltages
GB/T 156-2007 Standard voltages
GB/T 156-2017 Standard voltages
GB/Z 156-2025 Good practice for dynamic light scattering(DLS) measurements
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods
GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 13:Methods for general application—Measurement for determining the density—Water absorption tests—Shrinkage test
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test
GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 41:Methods specific to polyethylene and polypropylene compounds—Resistance to environmental stress cracking—Measurement of the melt flow index—Carbon black and/or mineral filler content measurement in polyethylene by direct combustion—Measurement of carbon black content by thermo gravimetric analysis(TGA)—Assessment of carbon black dispersion in polyethylene using a microscope
GB/T 3048.10-1994 Test methods for determining electrical properties of electric cables and wires Spark of extruded anti-corrosion protective sheaths
GB/T 3048.10-2007 Test methods for electrical properties of electric cables and wires—Part 10:Spark test of extruded protective sheaths
GB/T 3048.12-1994 Test methods for determining electrical properties of electric cables and wires Partial discharge test
GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires—Part 12:Partial discharge test
GB/T 3048.12-2025 Test methods for electrical properties of electric cables and wires—Part 12:Partial discharge test
GB/T 3048.13-1992 Electric cables and wires—Method for impulse voltage test
GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires—Part 13:Impulse voltage test
GB/T 3048.13-2025 Test methods for electrical properties of electric cables and wires—Part 13:Impulse voltage test
GB/T 3956-1997 Conductors of insulated cables
GB/T 3956-2008 Conductors of insulated cables
GB 6995.3-1986 Markings for electric cables and wires Part 3:Identifications of cables and wires
GB/T 6995.3-2008 Markings for electric wires and cables—Part 3:Identifications of cables and wires
GB/T 7113.2-2005 Flexible insulating sleeving—Methods of test
GB/T 7113.2-2014 Flexible insulating sleeving—Part 2:Methods of test
GB/T 8170-1987 Rules for rounding off of numberical values
GB/T 8170-2008 Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 11017.2-2014 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110 kV (Um=126 kV)—Part 2:Power cables
GB/T 11091-2005 Copper strips for cables
GB/T 11091-2014 Copper strip for cables
GB/T 11091-2024 Copper strip and foil for cables
GB/T 12706.1-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV)—Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV)
GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 16927.1-1997 High-voltage test techniques Part 1:General test requirements
GB/T 16927.1-2011 High-voltage test techniques—Part 1:General definitions and test requirements
GB/T 16927.3-2010 High voltage test techniques—Part 3:Definitions and requirements for on-site testing
GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables Part 1:Determination of the amount of halogen acid gas
GB/T 17650.1-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 1:Determination of the halogen acid gas content
GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity
GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 2:Determination of acidity (by pH measurement) and conductivity
GB/T 18380.11-2008 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus
GB/T 18380.11-2022 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.12-2022 Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.13-2008 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles
GB/T 18380.13-2022 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles
GB/T 18380.33-2008 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.33-2022 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.34-2008 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.34-2022 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C
GB/T 18380.35-2022 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mountedbunched wires or cables—Category C
GB/T 18380.36-2008 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D
GB/T 18380.36-2022 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D
GB/T 19666-2005 Flame retardant and fire resistant wires and cables
GB/T 19666-2019 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
JB/T 8137.1-1995 JB/T 8137.1-1995 - Specifications for the form and size of delivery racks for electric cables and wires
JB/T 8137.1-2013 Wire and Cable Delivery Tray - Part 1: General requirements
JB/T 8137.1-1999 JB/T 8137.1-1999 Electric wires and cables delivered on a plate - Part 1: General provisions
JB/T 8137.2-1995 JB/T 8137.2-1995 wire and cable delivery disk technical requirements
JB/T 8137.2-2013 Wiring Cable Delivery Tray - Part 2: Full Wooden Construction Delivery Tray (English)
JB/T 8137.2-1999 Wiring Cable Delivery Tray - Part 2: Full Wooden Construction Delivery Tray
JB/T 8137.3-2013 Wiring Cable Delivery Tray Part 3: Full Steelcorrugated Delivery Tray
JB/T 8137.3-1999 Delivery tray for cables and wires - Part 3: Full steel corrugated structure delivery tray
JB/T 8137.4-2013 Electric Cable and Wire Delivery Tray - Part 4: Steel Composite Structure Delivery Tray
JB/T 8137.4-1999 Wiring Harness Delivery Vessel - Part 4: Steel and Composite Structure Delivery Vessels
JB/T 8996-2014 JBT 8996-2014 Selection guidelines for high-voltage cables
JB/T 8996-1999 JB/T 8996-1999 High-voltage cable selection guidelines
IEC 60229:2007
IEC 61034-2
ISO 48
Adopt standards
IEC 60502-2:2014
Related Standards
GB/T 4012-1983
Replaced
GB/T 4012-1983 2.6/9.5mm composite coaxial cable for telecommunication use
GB/T 5441.10-1985
Replaced
GB/T 5441.10-1985 Test methods for communication cable—Measurement of actual length of coaxial pair—Sine wave method
GB/T 5441.1-1985
Replaced
GB/T 5441.1-1985 Test methods for communication cable General
GB/T 5441.2-1985
Replaced
GB/T 5441.2-1985 Test methods for communication cable Capacitance test Bridge method
GB/T 5441.3-1985
Replaced