GB 32276-2025
Active
National standards
force_standard
GB 32276-2025 Safety specification for dust explosion protection in textile industry
GB 32276-2025 Safety specification for dust explosion protection in textile industry
Basic Information
Standard Code:
GB 32276-2025
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
yes
CCS Name:
Fire and explosion prevention safety technology in factories
ICS Name:
Explosion-proof
Publish Date:
2025-10-31
Implement Date:
2026-05-01
Pages:
16 pages
Scope
This document specifies the division and scope of dust explosion hazardous areas in the textile industry, the general requirements for dust explosion prevention, building requirements, ventilation system requirements, dust removal system requirements, explosion control measures, electrical requirements, and operational safety management requirements, and describes the corresponding verification methods.
This document is applicable to the design, operation, and safety management of dust explosion hazardous areas and dust removal systems in the textile industry, which use cotton, linen, wool, blends, chemical fibers, and silk as raw materials.
Development Information
Replace the following standards
GB 19881-2005 Safety regulation for dust explosion prevention in flax fiber processing system
GB 32275-2015 Technical specifications of pipeline safety apparatus for fire dampers and explosion protection in textile industry
GB 32276-2015 Safety regulations for dust explosion protection in textile industry
Referenced Standards
GB 3836.1-2000 Electrical apparatus for explosive gas atmospheres—Part 1:General requirements
GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
GB/T 3836.1-2021 Explosive atmospheres—Part 1:Equipment—General requirements
GB 3836.15-2000 Electrical apparatus for explosive gas atmospheres—Part 15:Electrical installations in hazardous areas (other than mines)
GB/T 3836.15-2017 Explosive atmospheres—Part 15:Electrical installations design,selection and erection
GB 3836.15-2024 Explosive atmospheres—Part 15:Specification of electrical installations design,selection and erection
GB 3836.16-2006 Electrical apparatus for explosive gas atmospheres—Part 16:Inspection and maintenance of electrical installation(other than mines)
GB/T 3836.16-2017 Explosive atmospheres—Part 16:Electrical installations inspection and maintenance
GB/T 3836.16-2022 Explosive atmospheres—Part 16:Electrical installations inspection and maintenance
GB 3836.16-2024 Explosive atmospheres—Part 16:Specification of electrical installations inspection and maintenance
GB 12158-1990 General quideline for preventing electrostatic accidents
GB 12158-2006 General guideline for preventing electrostatic accidents
GB 12158-2024 General requirements for preventing electrostatic accidents
GB 15577-1995 Safety regulations for dust explosion prevention and protection
GB 15577-2007 Safety regulations for dust explosion prevention and protection
GB 15577-2018 Safety regulations for dust explosion prevention and protection
GB/T 15604-1995 Terminology for dust explosion prevention
GB/T 15604-2008 Terminology for dust explosion prevention
GB/T 15604-2024 Terminology for dust explosion prevention and protection
GB 50016-2014 Code for fire protection design of buildings
GB 50057-2010 Code for design protection of structures against lightning
GB 50058-2014 Code for design of electrical installations in explosive atmospheres
GB 50565-2010 Code for design of textile engineering on fire protection and prevention
GB 55037-2022 Building Fire Protection General Standards
Related Standards
GB/T 15604-1995
Replaced
GB/T 15605-1995
Replaced
GB/T 15605-1995 Guide for venting of dust explosions
GB/T 16425-1996
Replaced
GB/T 16425-1996 Determination for minimum explosive concentration of dust cloud
GB/T 16430-1996
Replaced
GB/T 16430-1996 Determination of the minimum ignition temperature of dust layer
GB 16543-1996
Replaced
GB 16543-1996 Safety regulations for the explosion precautions of bituminous coal injection into blast furnace
GB 17440-1998
Replaced