JJF 1173-2007 Replaced

JJF 1173-2007 Calibration Specification of Measuring Receivers

This specification applies to the calibration of measurement receivers in the frequency range of 150kHz to 265GHz that are newly manufactured, newly purchased, in use, or repaired.

Publish Date: 2007-02-28

JJF 1174-2007 Replaced

JJF 1174-2007 Calibration Specification for Digital Signal Generator

This specification applies to the calibration of digital signal generators with a frequency range of 250 kHz to 6 GHz and modulation methods including BPSK, QPSK, π/4 DQPSK, 8PSK, 16QAM, 32QAM, 256QAM, FSK, and MSK (communication standards including NADC, GSM, PHS, DECT, IS-95 CDMA, CDMA2000, and WCDMA).

Publish Date: 2007-02-28

JJF 1175-2007 Replaced

JJF 1175-2007 Calibration Specification for Test Sieves

This specification is applicable to the calibration of metal wire woven nets with dimensions of (0020 to 125) mm and metal perforated plate test sieves with dimensions of (1 to 125) mm.

Publish Date: 2007-02-28

JJF 1176-2007 Replaced

JJF 1176-2007 Calibration Specification for(0~1 500)℃ Tungsten-Rhenium Thermocouples

This specification is applicable to the calibration of tungsten-rhenium thermocouples (hereinafter referred to as thermocouples) with a measurement range of 0℃ to 1,500℃ and non-removable protective tubes. The calibration of tungsten-rhenium thermocouples without protective tubes can also be carried out in accordance with this specification.

Publish Date: 2007-02-28

JJF 1164-2006 Replaced

JJF 1164-2006 Calibration Specification for Bench Top Gas Chromatography-Mass Spectrometers

This specification is applicable to the calibration of ion traps and quadrupole-type desktop gas chromatograph-mass spectrometers (hereinafter referred to as desktop GCMS). The calibration of other types of desktop GCMS can be carried out in accordance with this specification.

Publish Date: 2006-12-08

JJF 1149-2006 Replaced

JJF 1149-2006 Calibration Specification for Cardiac Defibrillators & Cardiac Defibrillator-monitors

This standard applies to the calibration of new, in-use, and repaired ordinary cardiac defibrillators (hereinafter referred to as defibrillators) and cardiac defibrillation monitors (hereinafter referred to as defibrillation monitors) in the defibrillation section (including the impact of the defibrillation section on the electrocardiogram monitoring section during defibrillation); it does not apply to the calibration of automatic external defibrillators and implantable defibrillators. The metrological characteristics and calibration of the electrocardiogram monitoring section of defibrillation monitors can be carried out in accordance with the relevant provisions of the JJG 760—2003 Electrocardiogram Monitor Calibration Procedure.

Publish Date: 2006-05-23

JJF 1154-2006 Replaced

JJF 1154-2006 Calibration Specification for Four-wheel alignmenter

This specification is applicable to the calibration of optical, electronic, and mechanical four-wheel alignment instruments.

Publish Date: 2006-05-23

JJF 1118-2004 Replaced

JJF 1118-2004 Calibration Specification for Global Positioning System(GPS)Receiver

This specification is applicable to the calibration of geodetic and navigation Global Positioning System (GPS) receivers of various accuracies (hereinafter referred to as GPS receivers).

Publish Date: 2004-06-08

JJF 1119-2004 Replaced

JJF 1119-2004 Calibration Specification for Electronic Level Meter

This specification is applicable to the calibration of digital display electronic level rulers with a resolution of 0.01°. Electronic level rulers with other resolutions can be calibrated in accordance with this specification.

Publish Date: 2004-06-04

JJF 1117-2004 Replaced

JJF 1117-2004 Specification for Comparison of Measuring Instrument

This standard applies to the organization, implementation, and evaluation of measurement instrument comparisons organized by metrology administrative departments at all levels of government (hereinafter referred to as "comparisons"), in order to ensure and check the accuracy and reliability of measurement instrument values and achieve traceability. Similar comparisons organized or initiated by other departments may also be used for reference.

Publish Date: 2004-03-02

JJF 1099-2003 Replaced

JJF 1099-2003 Calibration Specification of Roughness Comparison Specimens

This specification is applicable to the calibration of surface roughness comparison samples. It includes: samples processed by grinding, turning, boring, milling, inserting, planing, EDM, and polishing, or samples copied by electroforming using these samples as master models (motherboards), as well as "surface roughness standard parts" selected from batch-produced parts.

Publish Date: 2003-05-12

JJF 1100-2003 Replaced

JJF 1100-2003 Calibration Specification for Flat Equal Thickness Interferometers

This specification is applicable to the calibration of plane-type equal-thickness interferometers, but not to the calibration of similar interferometric devices that can only estimate the amount of bending of interference fringes.

Publish Date: 2003-05-12