GB/T 14808-2001
Replaced
GB/T 1984-2024
Active
National standards
GB/T 1984-2024 High-voltage alternating-current circuit-breakers
GB/T 1984-2024 High-voltage alternating-current circuit-breakers
Basic Information
Standard Code:
GB/T 1984-2024
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
High-voltage switchgear
ICS Name:
High-voltage switchgear and controllers
Publish Date:
2024-09-29
Implement Date:
2025-04-01
Pages:
240 pages
Scope
This document specifies the operating conditions, rated values, design and structure, type tests, and factory tests for high-voltage AC circuit breakers.
This document applies to three-pole high-voltage AC circuit breakers designed for installation indoors or outdoors and operating in three-phase power systems with voltages of 3 kV or higher and frequencies of 50 Hz. It also applies to the operating mechanisms and auxiliary equipment of circuit breakers.
The closing and opening test methods described in this document only include direct test methods. For composite test methods, please refer to GB/T 4473.
Development Information
Replace the following standards
Referenced Standards
GB/T 1985-2023 High-voltage alternating current disconnectors and earthing switches
GB/T 2900.20-2016 Electrotechnical terminology—High-voltage switchgear and controlgear
GB/T 3906-2020 Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
GB/T 4109-2022 Insulated bushings for alternating voltages above 1 000 V
GB/T 7674-2020 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
GB/T 11022-2020 Common specifications for high-voltage alternating-current switchgear and controlgear standards
GB/T 14598.151-2012 Measuring relays and protection equipment—Part 151:Functional requirements for over/under current protection
IEC TR 62271-306:2012+AMD1:2018
GB/T 762-2002 Standard current ratings
GB 2536-1990 Transformer oils
GB 2536-2011 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
GB/T 4473-1996 Synthetic testing of high-voltage alternating current circuit-breakers
GB/T 4473-2008 Synthetic testing of High-voltage alternating current circuit-breakers
GB/T 4473-2018 Synthetic testing of high-voltage alternating current circuit-breakers
GB/T 8905-1996 The guide for processing and measuring SF6 gas in power apparatus
GB/T 8905-2012 The guide for management and measuring SF6 gas in electrical equipment
GB/T 21413.1-2008 Railway applications—Electric equipment for rolling stock—Part 1:General service conditions and general rules
GB/T 21413.1-2018 Railway applications—Electric equipment for rolling stock—Part 1:General service conditions and general rules
GB/T 21413.2-2008 Railway applications—Electric equipment for rolling stock—Part 2:Electrotechnical components—General rules
GB/T 21413.2-2021 Railway applications—Electric equipment for rolling stock—Part 2:Electrotechnical components—General rules
GB/T 21413.3-2008 Railway applications—Electric equipment for rolling stock—Part 3:Electrotechnical components—Rules for d.c. circuit-breakers
GB/T 21413.3-2023 Railway applications—Electric equipment for rolling stock—Part 3: Electrotechnical components—Rules for DC circuit-breakers
GB/T 21413.4-2008 Railway applications—Electric equipment for rolling stock—Part4:Electrotechnical components—Rules for AC circuit-breakers
GB/T 21413.4-2023 Railway applications—Electric equipment for rolling stock—Part 4:Electrotechnical components—Rules for AC circuit-breakers
GB/T 21413.5-2008 Railway applications—Electric equipment for rolling stock—Part 5:Electrotechnical components—Rules for HV rules
GB/T 21413.5-2023 Railway applications—Electric equipment for rolling stock—Part 5:Electrotechnical components—Rules for HV fuses
GB/T 28534-2012 The health and environmental impact on release of sulphur hexafluoride(SF6)used in high-voltage switchgear and controlgear
GB/T 29489-2013 Inductive load switching for high-voltage alternating current switchgear and controlgear
GB/T 30846-2014 High-voltage alternating current circuit-breakers with intentionally non-simultaneous pole operation
GB/T 32580.1-2016 Railway applications—Fixed installations—Particular requirements for a.c. switchgear—Part1:Single-phase circuit-breakers with Un above 1 kV
JB 3855-1996 3.6-40.5kV Indoor AC High Voltage Vacuum Circuit Breaker
JB/T 3855-2008 High-voltage AC vacuum circuit breaker
JB/T 9694-2008 High-voltage AC SF6 circuit breaker
JB/T 9694-1999 JBT 9694-1999 General technical conditions for sulfur hexafluoride circuit breakers
GB 2536-2025 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
GB/T 32580.1-2026 Railway applications—Fixed installations—High voltage AC switchgear and transformers—Part 1:Circuit-breakers
Adopt standards
IEC 62271-100:2021
Related Standards
GB 1984-2003
Replaced
GB 1984-2003 High-voltage alternating-current circuit-breakers
GB 1985-2004
Replaced
GB 1985-2004 High-voltage alternating-current disconnectors and earthing switches
GB/T 4473-2008
Replaced
GB/T 4473-2008 Synthetic testing of High-voltage alternating current circuit-breakers
GB/T 22381-2008
Replaced
GB/T 22381-2008 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above—Fluid-filled and extruded insulation power cables—Fluid-filled and dry type cable-terminations
GB/T 22382-2008
Replaced