GB 3836.19-2010 Explosive atmospheres—Part 19:Fieldbus intrinsically safe concept(FISCO)

GB 3836.19-2010 Explosive atmospheres—Part 19:Fieldbus intrinsically safe concept(FISCO)

Publish Date: 2010-08-09 Implement Date: 2011-08-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB 3836.19-2010
Standard Type: National standards
Standard Status: Replaced
is_force_gb: yes
CCS Name: Explosion-proof electrical appliances
ICS Name: Electric equipment for use in explosive environments
Publish Date: 2010-08-09
Implement Date: 2011-08-01
Pages: 10 pages

Scope

This part of GB 3836 specifies the detailed content of the operating procedures for equipment, systems, and installations using the intrinsically safe concept of fieldbus (FISCO). This part is aimed at bus power supply systems designed in accordance with the GB/T 16657.2 fieldbus physical layer installation standard, which adopts the Manchester coding concept.
The structure and installation requirements of FISCO equipment and systems are determined by GB 3836.4, GB 3836.15, and GB 3836.18, except for the amendments in this part. The fieldbus devices can be protected by any of the protection methods listed in GB 3836.1 applicable to the designated area. In this case, the requirements of this part only apply to the parts of the equipment directly connected to the intrinsically safe bus or dedicated line.
Note 1: Certification according to FISCO requirements does not prevent equipment from undergoing regular certification and marking in accordance with GB3836.4, so that they can be used in other systems. Equipment that has already obtained certification before the release of this technical specification and does not need to meet the electrical parameters of this technical specification may be marked as "suitable for FISCO systems". If the results of the comparison of electrical parameters Uo, Io, Po with Ui, Ii, Pi show compatibility with other parts of the system, and all other requirements of this technical specification are also met, the equipment can be used in FISCO systems.
Note 2: A typical FISCO system is shown in Appendix A.
Note 3: Generally, the "ic" FISCO system is used in Zone 2 areas. The FISCO system is mainly used in Zone 1 and Zone 2 areas, and if there are special provisions in the document, it can also be used in Zone 0.
Note 4: The IEC 6007927:2005 standard introduces the FNICO concept, which involves fieldbus concepts with energy-limited type [nL] in Zone 2. This standard replaces the energy-limited concept with the "i

Development Information

Word Count: 16 Thousand words Pages: 10 pages

Same series standard

Superseded by the following standards

Referenced Standards

IEC 60079-14:2007 GB/T 2900.35-1998 Electrotechnical terminology electrical apparatus for explosive atmospheres GB/T 2900.35-2008 Electrotechnical terminology Equipment for explosive atmospheres GB/T 2900.35-2023 Electrotechnical terminology—Explosive atmospheres GB 3836.1-2000 Electrical apparatus for explosive gas atmospheres—Part 1:General requirements GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements GB/T 3836.1-2021 Explosive atmospheres—Part 1:Equipment—General requirements GB 3836.4-2000 Electrical apparatus for explosive gas atmospheres—Part 4:Intrinsic safety“i” GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety "i" GB/T 3836.4-2021 Explosive atmospheres—art 4:Equipment protection by intrinsic safety “i” GB 3836.8-2003 Electrical apparatus for explosive gas atmospheres—Part 8:Type of protection “n” GB 3836.8-2014 Explosive atmospheres—Part 8:Equipment protection by type of protection “n” GB/T 3836.8-2021 Explosive atmospheres—Part 8: Equipment protection by type of protection “n” GB 3836.15-2000 Electrical apparatus for explosive gas atmospheres—Part 15:Electrical installations in hazardous areas (other than mines) GB/T 3836.15-2017 Explosive atmospheres—Part 15:Electrical installations design,selection and erection GB 3836.15-2024 Explosive atmospheres—Part 15:Specification of electrical installations design,selection and erection GB 3836.18-2010 Explosive atmospheres—Part 18:Intrinsically safe system GB/T 3836.18-2017 Explosive atmospheres—Part 18:Intrinsically safe electrical systems GB/T 3836.18-2024 Explosive atmospheres—Part 18:Intrinsically safe electrical systems GB/T 16657.2-1996 Fieldbus standard for use in industrial control system—Part 2:Physical layer specification and service definition GB/T 16657.2-2008 Industrial communication networks—Fieldbus specifications—Part 2:Physical layer specification and service definition

Adopt standards

IEC 60079-27:2008