GB/T 28547-2023 Active National standards

GB/T 28547-2023 Selection and application recommendations of metal oxide surge arresters for a.c. systems

GB/T 28547-2023 Selection and application recommendations of metal oxide surge arresters for a.c. systems

Publish Date: 2023-12-28 Implement Date: 2024-04-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 28547-2023
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Surge protector
ICS Name: Other standards related to insulation
Publish Date: 2023-12-28
Implement Date: 2024-04-01
Publisher: 国家市场监督管理总局、国家标准化管理委员会
Technical Committee: 全国避雷器标准化技术委员会(SAC/TC 81)
Pages: 195 pages

Scope

本文件提供了标称电压大于1 kV的交流系统用避雷器的选择以及应用建议。
本文件适用于GB/T 11032—2020中定义的交流无间隙金属氧化物避雷器,GB/T 28182中定义的额定电压52 kV及以下带串联间隙避雷器,以及GB/T 32520、DL/T 815—2021中定义的用于架空输电线路和配电线路的金属氧化物避雷器。

Development Information

Drafting Units:

中国电力科学研究院有限公司、西安高压电器研究院股份有限公司、西安西电避雷器有限责任公司、西安交通大学、清华大学、厦门ABB避雷器有限公司、南方电网科学研究院有限责任公司、国网浙江省电力有限公司电力科学研究院、正泰电气股份有限公司、大连法伏安电器有限公司、恒大电气有限公司、西门子能源避雷器(无锡)有限公司、西安神电电器有限公司、国网四川省电力公司电力科学研究院、国网河南省电力公司电力科学研究院、金冠电气股份有限公司、平高东芝(廊坊)避雷器有限公司、宁波市镇海国创高压电器有限公司、大连北方避雷器有限公司、南阳金牛电气有限公司、中电普瑞电力工程有限公司、国网电力科学研究院武汉南瑞有限责任公司、抚顺电瓷制造有限公司、杭州永德电气有限公司、南阳中威电气有限公司、浙江中能电气有限公司、明电舍(郑州)电气工程有限公司、四川大学

Drafting Persons:

王保山、孙泉、何慧雯、熊易、王陆璐、何计谋、张博宇、郭洁、何金良、左中秋、赵霞、赵冬一、蔡汉生、弥璞、金祖山、李敬彪、孙光宝、刘飞、韩飞、贾东旭、崔涛、郭磊、徐学亭、姚玉锁、李凡、李向军、高永海、靳国青、王建生、车文俊、万帅、侯冰、姜成、陈成刚、黄佳瑞、黄勇、李媛、彭杨涵、时卫东、杨磊、马艾茜、孟鹏飞

Word Count: 379 Thousand words Pages: 195 pages

Replace the following standards

Referenced Standards

GB/T 311.1-2012 Insulation co-ordination—Part 1:Definitions,principles and rules GB/T 311.2-2013 Insulation co-ordination—Part 2:Application guide GB/T 2900.12-2008 Electrotechnical terminology—Surge arresters, low-voltage surge protective devices and components GB/T 2900.19-1994 Electrotechnical terminology High-voltage test technique and insulation co-ordination GB/T 11032-2020 Metal-oxide surge arresters without gaps for a.c. systems GB/T 24842-2018 Overvoltage and insulation coordination of 1 000 kV UHV AC transmission project GB/T 24845-2018 Specification of metal-oxide surge arresters without gaps for 1 000 kV a.c. system DL/T 815-2021 IEC 60099-4:2009 GB/T 311.4-2010 Insulation co-ordination—Part 4:Computational guide to insulation co-ordination and modeling of electrical networks GB 3906-1991 A.C. metal-enclosed switchgear for rated voltages of 3~35kV GB/T 3906-2006 Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV GB/T 3906-2020 Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV GB/T 4585-2004 Artificial pollution tests on high-voltage insulators to be used on a.c systems GB/T 4585-2024 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems GB/T 4585.1-1984 Artificial pollution tests on high-voltage insulators to be used on a.c.systems Salt-fog method GB/T 4585.2-1991 Artificial pollution tests on high-voltage insulators to be used on a.c.systems solid-layer method GB 7674-1997 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above GB/T 7674-2008 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above GB/T 7674-2020 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above GB/T 11022-1999 Common specifications for high-voltage switchgear and control gear standards GB/T 11022-2011 Common specifications for high-voltage switchgear and controlgear standards GB/T 11022-2020 Common specifications for high-voltage alternating-current switchgear and controlgear standards GB/T 13540-1992 Anti-seismic characteristic test for high-voltage switchgear GB/T 13540-2009 Seismic qualification for high-voltage switchgear and controlgear GB/T 26218.1-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 1:Definitions,information and general principles GB/T 26218.2-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 2:Ceramic and glass insulators for a.c.systems GB/T 26218.3-2011 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 3:Composite insulators for a.c.systems GB/T 28182-2011 Surge arresters containing series gapped structures with rated voltage 52 kV and less GB/T 28182-2024 Surge arresters containing series gapped structures with rated voltage 52 kV and less GB/T 32520-2016 Metal-oxide surge arresters with external series gap(EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV GB/T 32520-2024 Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Adopt standards

IEC 60099-5:2018

Related Standards

Contact Us