Scope

This document provides guidance on the safe application of low-voltage switchgear assemblies (hereinafter referred to as "switchgear assemblies") during their design, manufacture, sale, and use. It presents relevant information on the interface characteristics, information, structural key points, and performance requirements of low-voltage switchgear assemblies in terms of safety technology that need to be considered.
This document is applicable to all types of low-voltage switchgear assemblies in accordance with the GB/T 7251 series of standards.
Note: When the products covered by this document operate under the special operating conditions specified in GB/T 7251, corresponding additional provisions need to be added.

Development Information

Word Count: 77 Thousand words Pages: 39 pages

Replace the following standards

Referenced Standards

GB 16895.8-2000 Electrical installations of buildings—Part 7:Requirements for special installations or location—Section 706:Restrictive conducting locations GB/T 16895.8-2010 Low-voltage electrical installations—Part 7-706:Requirements for special installations or locations—Conducting locations with restricted movement GB/T 16895.9-2000 Electrical installations of building—Part 7:Requirements for special installations or location—Section 707:Earthing requirements for the electrical installation of data processing equipment GB/T 16895.10-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 45:Protection against undervoltage GB/T 16895.10-2010 Low-voltage electrical installations—Part 4-44: Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB/T 16895.10-2021 Low-voltage electrical installations—Part 4-44:Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB 16895.11-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 442-Protection of low-voltage installations against temporary overvoltages and faults between high-voltage systems and earth GB 16895.12-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 443:Protection against overvoltages of atmospheric origin or due to switching GB 16895.13-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section701:Locations containing a bath tub or shower basin GB/T 16895.13-2012 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB/T 16895.13-2022 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB 16895.14-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 703:Locations containing sauna heaters GB/T 16895.14-2010 Electrical installations of buildings—Part 7-703:Requirements for special installations or locations—Rooms and cabins containing sauna heaters GB/T 16895.15-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 523:Current-carrying capacities in wiring systems GB/T 16895.16-2002 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 444:Protection against electromagnetic interferences(EMI) in installations of buildings GB/T 16895.17-2002 Eletrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 548:Earthing arrangements and equipotential bonding for information technology installations GB/T 16895.18-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 51:Common rules GB/T 16895.18-2010 Electrical installations of buildings—Part 5-51:Selection and erection of electrical equipment—Common rules GB/T 16895.19-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 702:Swimming pools and other basins GB/T 16895.19-2017 Low-voltage electrical installations—Part 7-702:Requirements for special installations or locations—Swimming pools and fountains GB/T 16895.20-2003 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 55:Other equipment Section 551:Low-voltage generating sets GB/T 16895.20-2017 Low-voltage electrical installations—Part 5-55:Selection and erection of electrical equipment—Other equipment GB 16895.21-2004 Electrical installations of buildings—Part 4-41:Protection for safety-Protection against electric shock GB/T 16895.21-2011 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.21-2020 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.22-2004 Electrical installations of buildings—Part 5-53:Selection and erection of electrical equipment—Isolation, switching and control—Section 534:Devices for protection against overvoltages GB/T 16895.22-2022 Low-voltage electrical installations—Part 5-53: Selection and erection of electrical equipment—Devices for protection for safety, isolation, switching,control and monitoring GB/T 16895.23-2005 Electrical installations of buildings—Part 6-61:Verification—Initial verification GB/T 16895.23-2012 Low-voltage electrical installations—Part 6:Verification GB/T 16895.23-2020 Low-voltage electrical installations—Part 6:Verification GB/T 16895.24-2005 Electrical installations of buildings—Part 7-710:Requirements for special installations or locations— Medical locations GB/T 16895.24-2024 Low-voltage electrical installations—Part 7-710:Requirements for special installations or locations—Medical locations GB/T 16895.25-2005 Electrical installations of buildings—Part 7-711:Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.25-2022 Low voltage electrical installations—Part 7-711: Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.26-2005 Electrical installations of buildings—Part 7-740:Requirements for special installations or locations—Structures, amusement devices and booths at fairgrounds, amusement parks and circuses GB 16895.27-2006 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 705—Electrical installations of agricultural and horticultural premises GB/T 16895.27-2012 Low-voltage electrical installations—Part 7-705:Requirements for special installations or locations—Agricultural and horticultural premises GB/T 16895.28-2008 Electrical installations of buildings—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.28-2017 Low-voltage electrical installations—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.29-2008 Electrical installations of buildings—Part 7-713:Requirements for special installations or locations—Furniture GB/T 16895.30-2008 Electrical installations of buildings—Part 7-715:Requirements for special installations or locations—Extra-low-voltage lighting installations GB/T 16895.31-2008 Electrical installations of buildings—Part 7-717:Requirements for special installations or locations—Mobile or transportable units GB/T 16895.32-2008 Electrical installations of buildings—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.32-2021 Low voltage electrical installations—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.33-2017 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.33-2021 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.34-2018 Low-voltage electrical installations—Part 7-753:Requirements for special installations or locations—Heating cables and embedded heating systems GB/T 16895.35-2023 Low-voltage electrical installations—Part 8-1:Functional aspects—Energy efficiency GB/T 16895.36-2024 Low-voltage electrical installations—Part 7-722:Requirements for special installations or locations—Supplies for electric vehicles GB/T 16895.37-2025 Low-voltage electrical installations—Part 8-82:Functional aspects—Prosumer's low-voltage electrical installations GB/T 16895.38-2025 Low-voltage electrical installations—Part 5-57:Selection and erection of electrical equipment—Erection of stationary secondary batteries GB/T 17626.2-1998 Electromagnetic compatibility—Testing and measurement techniques—Electrostatic discharge immunity test GB/T 17626.2-2006 Electromagnetic compatibility—Testing and measurement techniques—Electrostatic discharge immunity test GB/T 17626.2-2018 Electromagnetic compatibility—Testing and measurement techniques—Electrostatic discharge immunity test GB/T 17626.3-1998 Electromagnetic compatibility—Testing and measurement techniques-Radiated, radio-frequency, electromagnetic field immunity test GB/T 17626.3-2006 Electromagnetic compatibility—Testing and measurement techniques—Radiated, radio-frequency, electromagnetic field immunity test GB/T 17626.3-2016 Electromagnetic compatibility—Testing and measurement techniques—Radiated,radio-frequency,electromagnetic field immunity test GB/T 17626.3-2023 Electromagnetic compatibility—Testing and measurement techniques—Part 3:Radiated,radio-frequency,electromagnetic field immunity test GB/T 17626.4-1998 Electromagnetic compatibility—Testing and measurement techniques—Electrical fast transient/burst immunity test GB/T 17626.4-2008 Electromagnetic compatibility—Testing and measurement techniques—Electrical fast transient/burst immunity test GB/T 17626.4-2018 Electromagnetic compatibility—Testing and measurement techniques—Electrical fast transient/burstimmunity test GB/T 17626.5-1999 Electromagnetic compatibility—Testing and measurement techniques—Surge immunity test GB/T 17626.5-2008 Electromagnetic compatibility—Testing and measurement techniques—Surge immunity test GB/T 17626.5-2019 Electromagnetic compatibility—Testing and measurement techniques—Surge immunity test GB/T 17626.6-1998 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances, induced by radio-frequency fields GB/T 17626.6-2008 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances,induced by radio-frequency fields GB/T 17626.6-2017 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances,induced by radio-frequency fields GB/T 17626.8-1998 Electromagnetic compatibility—Testing and measurement techniques—Power frequency magnetic field immunity test GB/T 17626.8-2006 Electromagnetic compatibility—Testing and measurement techniques—Power frequency magnetic field immunity test GB/T 17626.11-1999 Electromagnetic compatibility—Testing and measurement techniques—Voltage dips, short interruptions and voltage variations immunity tests GB/T 17626.11-2008 Electromagnetic compatibility—Testing and measurement techniques—Voltage dips,short interruptions and voltage variations immunity tests GB/T 17626.11-2023 Electromagnetic compatibility—Testing and measurement techniques—Part 11:Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase GB/T 17626.13-2006 Electromagnetic compatibility—Testing and measurement techniques—Harmonics and interharmonics including mains signalling at a.c. power port,low frequency immunity test GB/T 20138-2006 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts(IK code) GB/T 20138-2023 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts(IK code) GB/T 24276-2009 A method of temperature-rise assessment by extrapolation for partially type-tested assemblies(PTTA)of low-voltage switchgear and controlgear GB/T 24276-2017 A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation GB/T 24276-2025 A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation IEC 61082-1 IEC 81346-1 IEC 81364-2