Scope
This standard specifies the structure, models, requirements, test methods, inspection rules, marking, packaging, transportation, and storage of rated voltage 06/1 kV copper core plastic insulated prefabricated branch power cables (hereinafter referred to as prefabricated branch power cables).
This standard applies to rated voltage 06/1 kV copper core polyvinyl chloride, polyethylene, or cross-linked polyethylene insulated plastic sheathed prefabricated branch power cables.
This standard does not apply to other equipment and components selected for prefabricated branch power cable systems, such as power distribution devices, which should comply with their own technical standards.
Development Information
Referenced Standards
GB/T 2900.10-2001 Electrotechnical vocabulary—Electric cables
GB/T 2900.10-2013 Electrotechnical terminology—Electric cables
GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section one:Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section two:Thermal ageing methods
GB/T 2951.3-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section three:Methods for determining the density—Water absorption tests—Shrinkage test
GB/T 2951.4-1997 Common test methods for insulating and sheathing materials of electric cables—Part 1:Methods for general application—Section four:Test at low temperature
GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables—Part 2:Methods specific to elastomeric compounds— Section one:Ozone resistance test—Hot set test—Mineral oil immersion test
GB/T 2951.6-1997 Common test methods for insulating and sheathing materials of electric cables Part 3:Methods specific to PVC compounds Section one:Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.7-1997 Common test methods for insulating and sheathing materials of electric cables Part 3:Methods specific to PVC compounds Swction two:Loss of mass test—Thermal stability test
GB/T 2951.8-1997 Common test methods for insulating and sheathing materials of electric cables Part 4:Methods specific to polyethylene and polypropylene compounds—Section one:Resistance to environmental stress cracking—Wrapping test after thermal ageing in air—Measurement of the melt flow index—Carbon black and/or mineral filler content measurement in PE
GB/T 2951.9-1997 Common test methods for insulating and sheathing materials of electric cables Part 4:Methods specific to polyethylene and polypropylene compounds Section two:Elongation at break after pre-conditioning—Wraping test after pre-conditioning—Wrapping test after thermal ageing in air—Measurement of mass increase Long-term stability test(Appendix A) Test method for copper catalysed oxidative degradation(Appendix B)
GB/T 2951.10-1997 Common test methods for insulating and sheathing materials of electric cables—Part 5:Methods specific to filling compounds Section two:Drop-point—Separation of oil—Lower temperature brittleness—Total acid number—Absence of corrosive components—Permittivity at 23℃-D.C. resistivity at 23℃ and 100℃
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 11:Methods for general application—Measurement of thickness and overall dimensions—Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 12:Methods for general application—Thermal ageing methods
GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 13:Methods for general application—Measurement for determining the density—Water absorption tests—Shrinkage test
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 14:Methods for general application—Test at low temperature
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 21:Methods specific to elastomeric compounds—Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 31:Methods specific to PVC compounds—Pressure test at high temperature—Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 32:Methods specific to PVC compounds—Loss of mass test—Thermal stability test
GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 41:Methods specific to polyethylene and polypropylene compounds—Resistance to environmental stress cracking—Measurement of the melt flow index—Carbon black and/or mineral filler content measurement in polyethylene by direct combustion—Measurement of carbon black content by thermo gravimetric analysis(TGA)—Assessment of carbon black dispersion in polyethylene using a microscope
GB/T 2951.42-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 42:Methods specific to polyethylene and polypropylene compounds—Tensile strength and elongation at break after conditioning at elevated temperature—Wrapping test after conditioning at elevated temperature—Wrapping test after thermal ageing in air—Measurement of mass increase—Long-term stability test—Test method for copper-catalyzed oxidative degradation
GB/T 2951.51-2008 Common test methods for insulating and sheathing materials of electric and optical cables—Part 51:Methods specific to filling compounds—Drop point—Separation of oil—Lower temperature brittleness—Total acid number—Absence of corrosive components—Permittivity at 23 ℃—DC resistivity at 23 ℃ and 100 ℃
GB/T 2952.1-2008 Protective coverings for electric cables—Part 1:General
GB/T 2952.3-2008 Protective coverings for electric cables—Part 3:General protective coverings for cables with non-metallic sheath
GB/T 3048.6-1994 Test methods for determining electrical properties of electric cables and wires Determining insulation resistance Voltmeter-ammeter method
GB/T 3048.8-1994 Test methods for determining electrical properties of electric cables and wires A.C. voltage tests
GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test
GB/T 3048.8-2025 Test methods for electrical properties of electric cables and wires— Part 8:AC voltage test
GB/T 3956-1997 Conductors of insulated cables
GB/T 3956-2008 Conductors of insulated cables
GB 6995.1-1986 Markings for electric cables and wires Part 1:General requirements
GB/T 6995.1-2008 Markings for electric wires and cables—Part 1:General requirements
GB 6995.3-1986 Markings for electric cables and wires Part 3:Identifications of cables and wires
GB/T 6995.3-2008 Markings for electric wires and cables—Part 3:Identifications of cables and wires
GB/T 9327-1998
GB/T 12706.1-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV)—Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV)
GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1:Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 12706.2-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV)—Part 2:Cables for rated voltages from 6kV(Um=7.2kV)up to 30kV(Um=36kV)
GB/T 12706.2-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2:Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2:Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
GB/T 12706.3-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV)—Part 3:Cables for rated voltage of 35kV(Um=40.5kV)
GB/T 12706.3-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 3:Cables for rated voltage of 35 kV(Um=40.5 kV)
GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 3:Cables for rated voltages of 35 kV(Um=40.5 kV)
GB/T 12706.4-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV)—Part 4:Test requirements on accessories for cables with rated voltages from 6kV(Um=7.2kV)up to 35kV(Um=40.5kV)
GB/T 12706.4-2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 4:Test requirements on accessories for cables with rated voltages from 6 kV(Um=7.2 kV) up to 35 kV(Um=40.5 kV)
GB/T 12706.4-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV)up to 35 kV(Um=40.5 kV)—Part 4:Test requirements on accessories for cables with rated voltages from 6 kV(Um=7.2 kV)up to 35 kV(Um=40.5 kV)
GB/T 12666.1-1990 Test method on electric wires or cables under fire conditions Part 1:General
GB/T 12666.1-2008 Test method on a single wire or cable under fire conditions—Part 1:Vertical specimen flame test
GB/T 12666.2-2008 Test method on a single wire or cable under fire conditions—Part 2:Horizontal specimen flame test
GB/T 12666.3-1990 Test method on electric wires or cables under fire conditions Part 3:Test on a single horizontal insulated wire or cable
GB/T 12666.3-2008 Test method on a single wire or cable under fire conditions—Part 3:Slanting specimen flame test
GB/T 12666.4-1990 Test method on electric wires or cables under fire conditions Part 4:Test on a single slanting insulated wire or cable
GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables Part 1:Determination of the amount of halogen acid gas
GB/T 17650.1-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 1:Determination of the halogen acid gas content
GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables Part 2:Determination of degree of acidity of gases by measuring pH and conductivity
GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 2:Determination of acidity (by pH measurement) and conductivity
GB/T 17651.1-1998 Measurement of smoke density of cables burning under defined conditions Part 1:Test apparatus
GB/T 17651.1-2021 Measurement of smoke density of cables or optical fiber cables burning under defined conditions—Part 1:Test apparatus
GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions Part 2:Test procedure and requirements
GB/T 17651.2-2021 Measurement of smoke density of cables or optical fiber cables burning under defined conditions—Part 2:Test procedure and requirements
GB/T 18380.1-2001 Tests on electric cables under fire conditions Part 1:Test on a single vertical insulated wire or cable
GB/T 18380.2-2001 Tests on electric cables under fire conditions—Part 2:Test on a single small vertical insulated copper wire or cable
GB/T 18380.3-2001 Tests on electric cables under fire conditions—Part 3:Tests on bunched wires or cables
GB/T 18380.11-2008 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus
GB/T 18380.11-2022 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.12-2022 Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 18380.13-2008 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles
GB/T 18380.13-2022 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles
GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions—Part 21:Test for vertical flame propagation for a single small insulated wire or cable—Apparatus
GB/T 18380.22-2008 Tests on electric and optical fibre cables under fire conditions—Part 22:Test for vertical flame propagation for a single small insulated wire or cable—Procedure for diffusion flame
GB/T 18380.31-2008 Test on electric and optical fibre cables under fire conditions—Part 31:Test for vertical flame spread of vertically-mounted bunched wires or cables—Apparatus
GB/T 18380.31-2022 Tests on electric and optical fibre cables under fire conditions—Part 31:Test for vertical flame spread of vertically-mounted bunched wires or cables—Apparatus
GB/T 18380.32-2008 Tests on electric and optical fibre cables under fire conditions—Part 32:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A F/R
GB/T 18380.32-2022 Tests on electric and optical fibre cables under fire conditions—Part 32:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A F/R
GB/T 18380.33-2008 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.33-2022 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A
GB/T 18380.34-2008 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.34-2022 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B
GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C
GB/T 18380.35-2022 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mountedbunched wires or cables—Category C
GB/T 18380.36-2008 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D
GB/T 18380.36-2022 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D
JB/T 8137-1999
Related Standards
DZ/T 0101.12-1994
Active
JJG 204-1980
Active
JJG 204-1980 Meteorological Ventilation Psychrometer
SC 53-1980
Active
SC 53-1980 Transfer blade hydraulic steering gear repair quality standard
DZ 4-1981
Replaced
\nDZ 4-1981 Method for Compiling Product Models of Geological Instrumentation Equipment
SC 69-1982
Active
SC 69-1982 ZSS-12 Flash-type seawater desalination production device technical specifications
SC 72-1982
Active