This document specifies the electrical, thermal, and mechanical safety requirements and testing requirements for general-purpose isolation transformers and power supply devices with built-in isolation transformers. Transformers with electronic circuits are also included in this document.
Unless otherwise specified, the following term "transformer" includes general-purpose isolation transformers and power supply devices with built-in isolation transformers.
This document applies to (linear) power supply devices. For switching power supply devices, GB/T 19212.17 applies.
This document does not apply to transformers included in GB/T 1094.11.
This document applies to stationary or mobile, single-phase or multi-phase, air-cooled (self-cooling or air-cooled), independent or matched dry transformers. Their windings can be encapsulated or non-encapsulated.
The rated supply voltage does not exceed AC 1,000 V, and the rated supply frequency and internal operating frequency do not exceed 500 Hz.
The rated output does not exceed:
—— Single-phase transformers, 1 kVA;
—— Multi-phase transformers, 5 kVA.