GB/T 17211-1998
Replaced
GB/T 24843-2018
Active
National standards
GB/T 24843-2018 Technical specification of 1 000 kV single phaseoil-immersed auto-transformer
GB/T 24843-2018 Technical specification of 1 000 kV single phaseoil-immersed auto-transformer
Basic Information
Standard Code:
GB/T 24843-2018
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Transformer
ICS Name:
The transmission grid and the distribution grid
Publish Date:
2018-07-13
Implement Date:
2019-02-01
Pages:
19 pages
Scope
This standard specifies the performance parameters, structural requirements, testing and marking, packaging, and transportation requirements for 1,000 kV single-phase oil-immersed autotransformers. This standard applies to single-phase oil-immersed autotransformers with a voltage rating of 1,000 kV and a rated capacity of 1,000 MVA and 1,500 MVA.
Development Information
Replace the following standards
Referenced Standards
GB/T 1094.3-2003 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 5273-2016 Dimensional standardisation of terminals for high-voltage apparatus
IEC 60296:2012
GB 1094.1-1996 Power transformers—Part 1:General
GB/T 1094.1-2013 Power transformers—Part 1:General
GB 1094.2-1996 Power transformers—Part 2:Temperature rise
GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers
GB/T 1094.3-2003 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 1094.4-2005 Power transformers—Part 4:Guide to the lightning impulse and switching impulse testing—Power transformers and reactors
GB 1094.5-2003 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.5-2008 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.6-2011 Power transformers—Part 6:Reactors
GB/T 1094.7-2008 Power transformers—Part 7:Loading guide for oil-immersed power transformers
GB/T 1094.10-2003 Power transformers—Part10:Determination of sound levels
GB/T 1094.10-2022 Power transformers—Part 10:Determination of sound levels
GB/T 1094.11-2007 Power transformers—Part 11:Dry-type transformers
GB/T 1094.11-2022 Power transformers—Part 11:Dry-type transformers
GB/T 1094.12-2013 Power transformers—Part 12:Loading guide for dry-type power transformers
GB/Z 1094.14-2011 Power transformers—Part 14:Design and application of liquid-immersed transformers using high-temperature insulation material
GB/T 1094.14-2022 Power transformer—Part 14:Liquid-immersed power transformer using high-temperature insulation materials
GB/T 1094.15-2020 Power transformers—Part 15:Gas-filled power transformers
GB/T 1094.16-2013 Power transformers—Part 16:Transformers for wind turbine applications
GB/T 1094.18-2016 Power transformers—Part 18:Measurement of frequency response
GB/T 1094.23-2019 Power transformers—Part 23:DC magnetic bias suppression devices
GB/T 1094.101-2008 Power transformers—Part 10.1:Determination of sound levels—Application guide
GB/T 1094.101-2023 Power transformers—Part 101:Determination of sound levels—Application guide
GB 1094.1-1996 Power transformers—Part 1:General
GB/T 1094.1-2013 Power transformers—Part 1:General
GB 1094.2-1996 Power transformers—Part 2:Temperature rise
GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers
GB/T 1094.4-2005 Power transformers—Part 4:Guide to the lightning impulse and switching impulse testing—Power transformers and reactors
GB 1094.5-2003 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.5-2008 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.7-2008 Power transformers—Part 7:Loading guide for oil-immersed power transformers
GB/T 1094.10-2003 Power transformers—Part10:Determination of sound levels
GB/T 1094.10-2022 Power transformers—Part 10:Determination of sound levels
GB/T 2424.25-2000 Environmental testing for electric and electronic products—Part 3:Test guidance-Seismic test methods
GB 2536-1990 Transformer oils
GB 2536-2011 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
GB/T 2900.15-1997 Electrotechnical terminology Transformer, instrument transformer, voltage regulator and reactor
GB/T 10230.1-2007 Tap-changers—Part 1:Performance requirements and test methods
GB/T 10230.1-2019 Tap-changers—Part 1:Performance requirements and test methods
GB/T 1094.7-2024 Power transformers—Part 7:Loading guide for mineral-oil-immersed power transformers
GB/T 1094.7-2024 Power transformers—Part 7:Loading guide for mineral-oil-immersed power transformers
GB/T 2424.25-2024 Environmental testing—Part 3:Test guidance—Seismic test methods
GB 2536-2025 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
GB 50994-2014 Standard for aseismatic appraisal of electrical facilities in industrial plants
GB/T 1094.16-2025 Power transformers—Part 16:Transformers for wind turbine applications
Related Standards
GB/T 2900.52-2000
Replaced
GB/T 2900.52-2000 Electrotechnical terminology-Generation, transmission and distribution of electricity—Generation
GB/Z 24835-2009
Replaced
GB/Z 24835-2009 Regulation of operation and maintenance for 1 000 kV gas-insulated metal-enclosed switchgear
GB/Z 24842-2009
Replaced
GB/Z 24842-2009 Overvoltage and insulation coordination of 1000 kV UHV AC transmission project
GB/Z 24843-2009
Replaced
GB/Z 24843-2009 Technical specification of 1 000 kV single phase oil-immersed auto-transformer
GB/Z 24846-2009
Replaced