Scope

This standard specifies the technical requirements for installation couplers used for permanent connections in fixed installations, including their classification, marking, documentation, dimensions, structure, mechanical performance, electrical performance, and thermal performance. This standard applies to installation couplers with 2 to 5 lines, including the provided grounding line, with a rated voltage not exceeding and including 500 V AC and a rated connection capacity not exceeding and including 10 mm². They are intended for permanent connections of indoor electrical equipment. Installation couplers with additional contact voltages beyond the power supply voltage are not covered by this standard. Note 1: The installation couplers specified in this standard are used in prefabricated buildings, in installation cavities such as suspended floors and ceilings, or in cable tray systems, cable ladder systems, cable conduit systems, and cable trunking systems, or in commercial exhibition rooms, partition walls, and any similar applications, or in furniture complying with GB 16895.29. Note 2: Except for the power supply voltage, this standard may also be used to guide installation couplers with additional contact voltages (such couplers can refer to the technical requirements in this standard). An installation coupler consists of a female connector device and a male connector device. Except during initial installation, reconfiguration, or maintenance of the installation coupler's wiring system, the male installation coupler device intended for permanent connections is not designed for connection and disconnection under load, nor is it solely intended for connection and disconnection. This means that the installation coupler is designed for infrequent use. Installation couplers are not suitable for socket systems, nor for lamp connection devices complying with GB/T 31463, nor for lamp-matched couplers.

Development Information

Word Count: 66 Thousand words Pages: 40 pages

Superseded by the following standards

Referenced Standards

GB/T 4207-2003 Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions GB/T 4207-2012 Method for the determination of the proof and the comparative tracking indices of solid insulating materials GB/T 4207-2022 Method for the determination of the proof and the comparative tracking indices of solid insulating materials GB/T 4208-2008 Degrees of protection provided by enclosure(IP code) GB/T 5169.11-1997 Fire hazard testing for electric and electronic products—Test methods—Glow-wire end-product test and guidance GB/T 5169.11-2006 Fire hazard testing for electric and electronic products—Part 11:Glowing/hot-wire based test methods—Glow-wire flammability test method for end-products GB/T 5169.11-2017 Fire hazard testing for electric and electronic products—Part 11:Glowing/hot-wire based test methods—Glow-wire flammability test method for end-products(GWEPT) GB 13140.4-1998 Connecting devices for low voltage circuits for household and similar purposes Part 2:Particular requirements for connecting devices as separate entities with insulation piercing clamping units GB/T 13140.4-2008 Connecting devices for low-voltage circuits for household and similar purposes—Part 2:Particular requirements for connecting devices as separate entities with insulation piercing clamping units GB/T 16842-2008 Protection of persons and equipment by enclosures—Probe for verification GB 16895.1-1997 Electrical installations of buildings Part 1:Scope, object and fundamental principles GB/T 16895.1-2008 Low-voltage electrical installations—Part 1:Fundamental principles,assessment of general characteristics,definitions GB 16895.2-1997 Electrical installations of buildings—Part 4:Protection for safety Chapter 42:Protection against thermal effects GB/T 16895.2-2005 Electrical installations of buildings—Part 4-42:Protection for safety—Protection against thermal effects GB/T 16895.2-2017 Low-voltage electrical installations—Part 4-42:Protection for safety—Protection against thermal effects GB 16895.3-1997 Electrical installations of buildings Part 5:Selection and erection of electrical equipment Chapter 54:Earthing arrangements and protective conductors GB/T 16895.3-2004 Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment-Earthing arrangements, protective conductors and protective bonding conductors GB/T 16895.3-2017 Low-voltage electrical installations—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements and protective conductors GB/T 16895.3-2024 Low-voltage electrical installations—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements and protective conductors GB/T 16895.4-1997 Electrical installations of buildings Part 5:Selection and erection of electrical equipment Chapter 53:Switchgear and control gear GB 16895.5-2000 Electrical installations of buildings—Part 4:Protection for safety—Chapter 43:Protection against over current GB/T 16895.5-2012 Low-voltage electrical installations—Part 4-43:Protection for safety—Protection against overcurrent GB 16895.6-2000 Electrical installations of buildings—Part 5:Selection and erection of electric equipment—Chapter 52:Wiring systems GB/T 16895.6-2014 Low-voltage electrical installations—Part 5-52:Selection and erection of electrical equipment—Wiring systems GB 16895.7-2000 Electrical installations of buildings Part 7:Requirements for special installations or locations Section 704:Construction and demolition site installations GB/T 16895.7-2009 Low-voltage electrical installations—Part 7-704:Requirements for special installations or locations—Construction and demolition site installations GB/T 16895.7-2021 Low-voltage electrical installations—Part 7-704:Requirements for special installations or locations—Construction and demolition site installations GB 16895.8-2000 Electrical installations of buildings—Part 7:Requirements for special installations or location—Section 706:Restrictive conducting locations GB/T 16895.8-2010 Low-voltage electrical installations—Part 7-706:Requirements for special installations or locations—Conducting locations with restricted movement GB/T 16895.9-2000 Electrical installations of building—Part 7:Requirements for special installations or location—Section 707:Earthing requirements for the electrical installation of data processing equipment GB/T 16895.10-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 45:Protection against undervoltage GB/T 16895.10-2010 Low-voltage electrical installations—Part 4-44: Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB/T 16895.10-2021 Low-voltage electrical installations—Part 4-44:Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB 16895.11-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 442-Protection of low-voltage installations against temporary overvoltages and faults between high-voltage systems and earth GB 16895.12-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 443:Protection against overvoltages of atmospheric origin or due to switching GB 16895.13-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section701:Locations containing a bath tub or shower basin GB/T 16895.13-2012 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB/T 16895.13-2022 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB 16895.14-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 703:Locations containing sauna heaters GB/T 16895.14-2010 Electrical installations of buildings—Part 7-703:Requirements for special installations or locations—Rooms and cabins containing sauna heaters GB/T 16895.15-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 523:Current-carrying capacities in wiring systems GB/T 16895.16-2002 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 444:Protection against electromagnetic interferences(EMI) in installations of buildings GB/T 16895.17-2002 Eletrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 548:Earthing arrangements and equipotential bonding for information technology installations GB/T 16895.18-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 51:Common rules GB/T 16895.18-2010 Electrical installations of buildings—Part 5-51:Selection and erection of electrical equipment—Common rules GB/T 16895.19-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 702:Swimming pools and other basins GB/T 16895.19-2017 Low-voltage electrical installations—Part 7-702:Requirements for special installations or locations—Swimming pools and fountains GB/T 16895.20-2003 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 55:Other equipment Section 551:Low-voltage generating sets GB/T 16895.20-2017 Low-voltage electrical installations—Part 5-55:Selection and erection of electrical equipment—Other equipment GB 16895.21-2004 Electrical installations of buildings—Part 4-41:Protection for safety-Protection against electric shock GB/T 16895.21-2011 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.21-2020 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.22-2004 Electrical installations of buildings—Part 5-53:Selection and erection of electrical equipment—Isolation, switching and control—Section 534:Devices for protection against overvoltages GB/T 16895.22-2022 Low-voltage electrical installations—Part 5-53: Selection and erection of electrical equipment—Devices for protection for safety, isolation, switching,control and monitoring GB/T 16895.23-2005 Electrical installations of buildings—Part 6-61:Verification—Initial verification GB/T 16895.23-2012 Low-voltage electrical installations—Part 6:Verification GB/T 16895.23-2020 Low-voltage electrical installations—Part 6:Verification GB/T 16895.24-2005 Electrical installations of buildings—Part 7-710:Requirements for special installations or locations— Medical locations GB/T 16895.24-2024 Low-voltage electrical installations—Part 7-710:Requirements for special installations or locations—Medical locations GB/T 16895.25-2005 Electrical installations of buildings—Part 7-711:Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.25-2022 Low voltage electrical installations—Part 7-711: Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.26-2005 Electrical installations of buildings—Part 7-740:Requirements for special installations or locations—Structures, amusement devices and booths at fairgrounds, amusement parks and circuses GB 16895.27-2006 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 705—Electrical installations of agricultural and horticultural premises GB/T 16895.27-2012 Low-voltage electrical installations—Part 7-705:Requirements for special installations or locations—Agricultural and horticultural premises GB/T 16895.28-2008 Electrical installations of buildings—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.28-2017 Low-voltage electrical installations—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.29-2008 Electrical installations of buildings—Part 7-713:Requirements for special installations or locations—Furniture GB/T 16895.30-2008 Electrical installations of buildings—Part 7-715:Requirements for special installations or locations—Extra-low-voltage lighting installations GB/T 16895.31-2008 Electrical installations of buildings—Part 7-717:Requirements for special installations or locations—Mobile or transportable units GB/T 16895.32-2008 Electrical installations of buildings—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.32-2021 Low voltage electrical installations—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.33-2017 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.33-2021 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.34-2018 Low-voltage electrical installations—Part 7-753:Requirements for special installations or locations—Heating cables and embedded heating systems GB/T 16895.35-2023 Low-voltage electrical installations—Part 8-1:Functional aspects—Energy efficiency GB/T 16895.36-2024 Low-voltage electrical installations—Part 7-722:Requirements for special installations or locations—Supplies for electric vehicles GB/T 16895.37-2025 Low-voltage electrical installations—Part 8-82:Functional aspects—Prosumer's low-voltage electrical installations GB/T 16895.38-2025 Low-voltage electrical installations—Part 5-57:Selection and erection of electrical equipment—Erection of stationary secondary batteries GB/T 16935.1-2008 Insulation coordination for equipment within low-voltage systems—Part 1:Principles,requirements and tests GB/T 17464-2012 Connecting devices—Electrical copper conductors—Safety requirements for screw-type and screwless-type clamping units—General requirements and particular requirements for clamping units for conductors from 0.2 mm2 up to 35 mm2(included) IEC 60068-2-31:2008

Adopt standards

IEC 61535:2012

Related Standards