GB 12476.2-2010 Replaced National standards force_standard

GB 12476.2-2010 Electrical apparatus for use in the presence of combustible dust—Part 2:Selection and installation

GB 12476.2-2010 Electrical apparatus for use in the presence of combustible dust—Part 2:Selection and installation

Publish Date: 2010-08-09 Implement Date: 2011-08-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB 12476.2-2010
Standard Type: National standards
Standard Status: Replaced
is_force_gb: yes
CCS Name: Explosion-proof electrical appliances
ICS Name: Electric equipment for use in explosive environments
Publish Date: 2010-08-09
Implement Date: 2011-08-01
Pages: 27 pages

Development Information

Word Count: 49 Thousand words Pages: 27 pages

Same series standard

Replace the following standards

Superseded by the following standards

Referenced Standards

GB/T 4208-2008 Degrees of protection provided by enclosure(IP code) GB/T 6919-1986 Air quality—Vocabulary GB 12476.1-2000 Electrical apparatus for use in the presence of combustible dust—Part 1-1:Electrical apparatus protected by enclosures and surface temperature limitation—Specification for apparatus GB 12476.1-2013 Electrical apparatus for use in the presence of combustible dust—Part 1:General requirements GB 12476.3-2007 Electrical apparatus for use in the presence of combustible dust—Part 3:Classification of areas where combustible dusts are or may be present GB 12476.4-2010 Electrical apparatus for use in the presence of combustible dust—Part 4:Protection by intrinsic safety“iD” GB 12476.6-2010 Electrical apparatus for use in the presence of combustible dust—Part 6:Protection by encapsulation "mD" GB 12476.7-2010 Electrical apparatus for use in the presence of combustible dust—Part 7:Type of protection "pD" GB/T 12476.8-2010 Electrical apparatus for use in the presence of combustible dust—Part 8:Test methods—Methods for determining the minimum ignition temperatures of dust GB 16895.1-1997 Electrical installations of buildings Part 1:Scope, object and fundamental principles GB/T 16895.1-2008 Low-voltage electrical installations—Part 1:Fundamental principles,assessment of general characteristics,definitions GB 16895.2-1997 Electrical installations of buildings—Part 4:Protection for safety Chapter 42:Protection against thermal effects GB/T 16895.2-2005 Electrical installations of buildings—Part 4-42:Protection for safety—Protection against thermal effects GB/T 16895.2-2017 Low-voltage electrical installations—Part 4-42:Protection for safety—Protection against thermal effects GB 16895.3-1997 Electrical installations of buildings Part 5:Selection and erection of electrical equipment Chapter 54:Earthing arrangements and protective conductors GB/T 16895.3-2004 Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment-Earthing arrangements, protective conductors and protective bonding conductors GB/T 16895.3-2017 Low-voltage electrical installations—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements and protective conductors GB/T 16895.3-2024 Low-voltage electrical installations—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements and protective conductors GB/T 16895.4-1997 Electrical installations of buildings Part 5:Selection and erection of electrical equipment Chapter 53:Switchgear and control gear GB 16895.5-2000 Electrical installations of buildings—Part 4:Protection for safety—Chapter 43:Protection against over current GB/T 16895.5-2012 Low-voltage electrical installations—Part 4-43:Protection for safety—Protection against overcurrent GB 16895.6-2000 Electrical installations of buildings—Part 5:Selection and erection of electric equipment—Chapter 52:Wiring systems GB/T 16895.6-2014 Low-voltage electrical installations—Part 5-52:Selection and erection of electrical equipment—Wiring systems GB 16895.7-2000 Electrical installations of buildings Part 7:Requirements for special installations or locations Section 704:Construction and demolition site installations GB/T 16895.7-2009 Low-voltage electrical installations—Part 7-704:Requirements for special installations or locations—Construction and demolition site installations GB/T 16895.7-2021 Low-voltage electrical installations—Part 7-704:Requirements for special installations or locations—Construction and demolition site installations GB 16895.8-2000 Electrical installations of buildings—Part 7:Requirements for special installations or location—Section 706:Restrictive conducting locations GB/T 16895.8-2010 Low-voltage electrical installations—Part 7-706:Requirements for special installations or locations—Conducting locations with restricted movement GB/T 16895.9-2000 Electrical installations of building—Part 7:Requirements for special installations or location—Section 707:Earthing requirements for the electrical installation of data processing equipment GB/T 16895.10-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 45:Protection against undervoltage GB/T 16895.10-2010 Low-voltage electrical installations—Part 4-44: Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB/T 16895.10-2021 Low-voltage electrical installations—Part 4-44:Protection for safety—Protection against voltage disturbances and electromagnetic disturbances GB 16895.11-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 442-Protection of low-voltage installations against temporary overvoltages and faults between high-voltage systems and earth GB 16895.12-2001 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 443:Protection against overvoltages of atmospheric origin or due to switching GB 16895.13-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section701:Locations containing a bath tub or shower basin GB/T 16895.13-2012 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB/T 16895.13-2022 Low-voltage electrical installations—Part 7-701:Requirements for special installations or locations—Locations containing a bath or shower GB 16895.14-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 703:Locations containing sauna heaters GB/T 16895.14-2010 Electrical installations of buildings—Part 7-703:Requirements for special installations or locations—Rooms and cabins containing sauna heaters GB/T 16895.15-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 523:Current-carrying capacities in wiring systems GB/T 16895.16-2002 Electrical installations of buildings—Part 4:Protection for safety—Chapter 44:Protection against overvoltages—Section 444:Protection against electromagnetic interferences(EMI) in installations of buildings GB/T 16895.17-2002 Eletrical installations of buildings—Part 5:Selection and erection of electrical equipment—Section 548:Earthing arrangements and equipotential bonding for information technology installations GB/T 16895.18-2002 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 51:Common rules GB/T 16895.18-2010 Electrical installations of buildings—Part 5-51:Selection and erection of electrical equipment—Common rules GB/T 16895.19-2002 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 702:Swimming pools and other basins GB/T 16895.19-2017 Low-voltage electrical installations—Part 7-702:Requirements for special installations or locations—Swimming pools and fountains GB/T 16895.20-2003 Electrical installations of buildings—Part 5:Selection and erection of electrical equipment Chapter 55:Other equipment Section 551:Low-voltage generating sets GB/T 16895.20-2017 Low-voltage electrical installations—Part 5-55:Selection and erection of electrical equipment—Other equipment GB 16895.21-2004 Electrical installations of buildings—Part 4-41:Protection for safety-Protection against electric shock GB/T 16895.21-2011 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.21-2020 Low-voltage electrical installations—Part 4-41:Protection for safety—Protection against electric shock GB/T 16895.22-2004 Electrical installations of buildings—Part 5-53:Selection and erection of electrical equipment—Isolation, switching and control—Section 534:Devices for protection against overvoltages GB/T 16895.22-2022 Low-voltage electrical installations—Part 5-53: Selection and erection of electrical equipment—Devices for protection for safety, isolation, switching,control and monitoring GB/T 16895.23-2005 Electrical installations of buildings—Part 6-61:Verification—Initial verification GB/T 16895.23-2012 Low-voltage electrical installations—Part 6:Verification GB/T 16895.23-2020 Low-voltage electrical installations—Part 6:Verification GB/T 16895.24-2005 Electrical installations of buildings—Part 7-710:Requirements for special installations or locations— Medical locations GB/T 16895.24-2024 Low-voltage electrical installations—Part 7-710:Requirements for special installations or locations—Medical locations GB/T 16895.25-2005 Electrical installations of buildings—Part 7-711:Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.25-2022 Low voltage electrical installations—Part 7-711: Requirements for special installations or locations—Exhibitions, shows and stands GB/T 16895.26-2005 Electrical installations of buildings—Part 7-740:Requirements for special installations or locations—Structures, amusement devices and booths at fairgrounds, amusement parks and circuses GB 16895.27-2006 Electrical installations of buildings—Part 7:Requirements for special installations or locations—Section 705—Electrical installations of agricultural and horticultural premises GB/T 16895.27-2012 Low-voltage electrical installations—Part 7-705:Requirements for special installations or locations—Agricultural and horticultural premises GB/T 16895.28-2008 Electrical installations of buildings—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.28-2017 Low-voltage electrical installations—Part 7-714:Requirements for special installations or locations—External lighting installations GB/T 16895.29-2008 Electrical installations of buildings—Part 7-713:Requirements for special installations or locations—Furniture GB/T 16895.30-2008 Electrical installations of buildings—Part 7-715:Requirements for special installations or locations—Extra-low-voltage lighting installations GB/T 16895.31-2008 Electrical installations of buildings—Part 7-717:Requirements for special installations or locations—Mobile or transportable units GB/T 16895.32-2008 Electrical installations of buildings—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.32-2021 Low voltage electrical installations—Part 7-712:Requirements for special installations or locations—Solar photovoltaic (PV) power supply systems GB/T 16895.33-2017 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.33-2021 Low-voltage electrical installations—Part 5-56:Selection and erection of electrical equipment—Safety services GB/T 16895.34-2018 Low-voltage electrical installations—Part 7-753:Requirements for special installations or locations—Heating cables and embedded heating systems GB/T 16895.35-2023 Low-voltage electrical installations—Part 8-1:Functional aspects—Energy efficiency GB/T 16895.36-2024 Low-voltage electrical installations—Part 7-722:Requirements for special installations or locations—Supplies for electric vehicles GB/T 16895.37-2025 Low-voltage electrical installations—Part 8-82:Functional aspects—Prosumer's low-voltage electrical installations GB/T 16895.38-2025 Low-voltage electrical installations—Part 5-57:Selection and erection of electrical equipment—Erection of stationary secondary batteries GB 16895.21-2004 Electrical installations of buildings—Part 4-41:Protection for safety-Protection against electric shock GB 19212.1-2008 Safety of power transformers,power supplies,reactors and similar products—Part 1:General requirements and tests IEC 61024-1 IEC 61024-1-1 IEC 61241-0:2004 IEC 61241-1:2004 IEC 61241-17

Adopt standards

IEC 61241-14:2004

Related Standards

Contact Us